– 50 –
3. Buzzer Circuit
When the buzzer is to be activated, buzzer output pin
30
of the micro computer alternates between ON and
OFF repeatedly at 4kHz and Q302 is turned ON/OFF accordingly. A 4kHz voltage is applied to the buzzer
and the diaphragm of the buzzer vibrates to output 4kHz sound.
4. Initial setting (IC301)
The pre-heating operation start value, ratings of the compressor, maximum rotation speed, etc. are preset
in the micro computer.
5. Receive circuit
Infrared signals from the wireless remote controller are received by the light receiving unit and output after
being ampli
fi
ed and shaped.