background image

< S818 : 

A

 >

 3 

 1 

 2 

 5 

 6 

 4 

 8 

No.

Item

Qty

7

Remote

Controller

1

8

Insulator

1

            (t3 x 160 x 600)

9

Screw for Overturn
Prevention

2

                       (4.0 

×

 34)

0

Insulator

1

              (20 

×

 30 

×

 300)

-

Bush

3

2.3 Connecting the pipe to indoor unit

• Draw in the pipes through the hole of the wall or the floor to indoor.
• Arrange the pipe shown below. In the case that large pipe and small

pipe arrange to make in front and behind.

• The indoor piping should be insulated with the enclosed insulation

pipe.

• The pipe should first be cut longer than the length shown below.
• The excess section of the pipe should be cut off during pipe connection.

1. Installation of wall penetration and installation of protection pipe

1.1 Hole position

• Make a hole on the wall such

the position as shown below,
in order to keep the flow for
condensed water smooth.

• Carefully read through the procedures of proper installation

before starting installation work.

• The sales agent should inform customers regarding the correct

operation of installation.

Tools Needed For Installation Work

(Mark       is exclusive use tool for R410A)  •  

ª ·

 Screwdriver

• Measuring Tape • Knife • Saw • ø65mm Power Drill
• Hexagonal Wrench Key (           4mm)  • Wrench (14,17,19,
22mm)     Gas leakage Detector • Pipe Cutter • Putty
• Vinyl Tape • Pliers  • Flare Tool       Vacuum Pump Adapter
     Manifold Valve         Charge Hose         Vacuum Pump

FOR SERVICE PERSONNEL ONLY

 7 

INDOOR UNIT / OUTDOOR UNIT

RAF-25

08!

 / RAC-25

&8!

RAF-35

08!

 / RAC-35

&8!

RAF-50

08!

 / RAC-50

&8!

HITACHI SPLIT UNIT AIR CONDITIONER

INSTALLATION MANUAL

SAFETY PRECAUTION

• Read the safety precautions carefully before operating the unit.
• The contents of this section are vital to ensure safety. Please pay special attention to the following sign.

WARNING ............. Incorrect methods of installation may cause death or serious injury.
CAUTION .............. Improper installation may result in serious consequence.
Make sure to connect earth line.
This sign in the figures indicates prohibition.

Be sure that the unit operates in proper condition after installation. Explain to customer the proper operation and maintenance of the unit
as described in the user’s guide. Ask customers to keep this installation manual together with the instruction manual.

 WARNING

• Please request your sales agent or qualified technician to install your unit. Water leakage, short circuit or fire may occur if you do the installation work

yourself.

• Please observe the installation stated in the installation manual during the process of installation. Improper installation may cause water leakage, electric

shock and fire.

• Make sure that the units are mounted at locations which are able to provide full support to the weight of the units. If not, the units may collapse and

impose danger.

• Observe the rules and regulations of the electrical installation and the methods described in the installation manual when dealing with the electrical work.

Use cables which are approved official in your country. Be sure to use the specified circuit. A short circuit and fire may occur due to the use of low quality
wire or improper work.

• Be sure to use the specified cables for connecting the indoor and outdoor units. Please ensure that the connections are tight after the conductors of the

wire are inserted into the terminals to prevent the external force is being applied to the connection section of the terminal base. Improper insertion and
loose contact may cause over-heating and fire.

• Please use the specified components for installation work. Otherwise, the unit may collapse or water leakage, electric shock, fire or stronger vibration

may occur.

• Be sure to use the specified piping set for R410A. Otherwise, this may result in broken copper pipes or faults.

• When installing or transferring an air conditioner to another location, make sure that air other than the specified refrigerant (R410A) does not enter the

refrigeration cycle. If other air should enter, the pressure level of the refrigeration cycle may increase abnormally which could result in a rupture and injury.

• Be sure to ventilate fully if a refrigerant gas leak while at work. If the refrigerant gas comes into contact with fire, a poisonous gas may occur.

• After completion of installation work, check to make sure that there is no refrigeration gas leakage. If the refrigerant gas leaks into the room, coming into

contact with fire in the fan-driven heater, space heater, etc., a poisonous gas may occur.

• Unauthorized modifications to the air conditioner may be dangerous. If a breakdown occurs please call a qualified air conditioner technician or electrician.

Improper repairs may result in water leakage, electric shock and fire, etc.

• Be sure to connect the earth line from the power supply wire to the outdoor unit and between the outdoor and indoor unit. Do not

connect the earth line to the gas tube, water pipe, lighting rod or the earth line of the telephone unit. Improper earthing may cause
electric shocks.

• When finishing the refrigerant collection (pumping down), stop the compressor and then remove the coolant pipe. If you remove the refrigerant pipe while

the compressor is operating and the service valve is released, air is sucked and a pressure in the freezing cycle system will build up steeply, causing an
explosion or injury.

• When installing the unit, be sure to install the refrigerant pipe before starting the compressor.

If the refrigerant pipe is not installed and the compressor is operated with the service valve released, air is sucked and the pressure level of the
refrigeration cycle may increase abnormally which could result in a rupture and injury.

 CAUTION

• A circuit breaker must be installed in the house distribution box for the direct connected power supply cables to the outdoor unit. In case of other

installations a main switch with a contact gap or more than 3mm has to be installed. Without a circuit breaker, the danger of electric shock exists.

• Do not install the unit near a location where there is flammable gas. The outdoor unit may catch fire if flammable gas leaks around

it.

• Please ensure smooth flow of water when installing the drain hose. Improper installing may wet your furniture.

• An IEC approved power cord should be used. Power cord type: NYM.

Names of Indoor Components

INDOOR UNIT

THE CHOICE OF MOUNTING SITE

  (Please note the following matters and obtain permission from customer before installation.)

 WARNING

• The unit should be mounted at stable, non-vibratory location which

can provide full support to the unit.

 CAUTION

• No nearby heat source and no obstruction near the air outlet is

allowed.

• The clearance distances from top, right and left are specified in

figure below.

• The location must be convenient for water drainage and pipe

connection with the outdoor unit.

• To avoid interference from noise, please place the unit and its

remote controller at least 1m from the radio and television.

• To avoid any error in signal transmission from the remote controller,

please put the controller far away from high-frequency machines
and high-power wireless systems.

OUTDOOR UNIT

 WARNING

• The outdoor unit must be mounted at a location which can support

heavy weight. Otherwise, noise and vibration will increase.

 CAUTION

• Do not expose the unit under direct sunshine or rain. Besides,

ventilation must be good and clear of obstruction.

• The air blown out of the unit should not point directly to animals or

plants.

• The clearances of the unit from top, left, right and front are specified

in figure below. At least two of the above sides must be open air.

• The installation height should be at least 2,300mm or more from the

floor.

• Be sure that the hot air blown out of the unit and noise do not disturb

the neighbourhood.

• Do not install at a location where there is flammable gas, steam, oil

and smoke.

• The location must be convenient for water drainage.
• Place the outdoor unit and its connecting cord at least 1m away from

the antenna or signal line of television, radio or telephone. This is to
avoid noise interference.

1.2 Wall penetration and installation of

protection pipe

• Drill a ø65mm hole on wall which is slightly

tilted towards the outdoor side. Drill the wall
at a small angle.

• Cut the protection pipe according to the wall

thickness.

• Empty gap in the sleeve of protection pipe

should be completely sealed with putty to
avoid dripping of rain water into the room.

 CAUTION

Be sure that the wire is not in
contact with any metal in the
wall. Please use the protection
pipe as wire passing through
the hollow part of the wall so
as to prevent the possibility of
damaged by mouse.

Indoor

Outdoor

Seal with
putty

2~5mm

WALL

Seal with
putty

Sleeve of
protection pipe

Protection
pipe

2. Installation of the indoor unit

2.1 How to remove the front cover

Please refer to section for details.

Front cover
bushing

Bushing
(2 pieces on
each side)

2.2 Drain pipe

• Make sure drain pipe slopes downward so that drain flows smoothly without being trapped in the middle.
• The drain hose (connecting port outer diameter: 16mm or 20mm, length: 500mm) is included in the indoor unit. Prepare

a drain pipe as shown in the following figure.

• To prevent condensation, the indoor drain pipe should be covered with heat insulation material with a thickness of more

than 10mm.

• After piping is completed, check to make sure that drain discharges smoothly. Seal the drain pipe tightly with tape to

keep dirt out.

Front view

Right side view

88

210

96

500

Drain hose

Make sure the drain hose
slopes downward.

Drain pipe (procure locally)

(Unit: mm)

Cabinet

For floor piping

• For floor piping, cut the front

cover bushing with a plastic
cutter or similar tool and use
a file for an attractive finish.

For sideways piping

• For right sideways piping,

cut the stand’s bushing
with a plastic cutter or
similar tool and use a file
for an attractive finish.

If there is a baseboard

• If the baseboard is 5~15mm

in thickness and 115mm or
less in height, cut the pipe
bushing to conform to the
baseboard.

11

5

70

5

15

Baseboard

Cabinet

Removal and installation
of front cover

Screw (3 pieces)

Connecting section

Screw (3 pieces)

80~100mm

65mm

Drain hose
make lower
than center of
the hole.

55mm

184mm or less

Hole Position

In the case of making a hole on the
wall.

In the case of making a hole on
the floor.

INDOOR UNIT

40

180

R80

130

170

R60

40

180

R80

170

40

340

40

 WARNING

• For sideways piping, do not install the drain

hose sideways. Connect the drain hose so that
it comes out directly.

• Sideways installation of the drain hose will

prevent it from sloping downward, causing
water leakage. To avoid dripping, make sure to
pass the drain hose under the pipe.

PIPE SUPPORT

PIPE SUPPORT

Screws

Mount PIPE SUPPORT so that the cylindrical portion of the drain pan passes
through its hole and secure it with screws located at the right back corner.

Hook the PIPE
SUPPORT tab in
the square hole.

• Since there is some space between PIPE SUPPORT and

the pipe, affix the insulator 

0

 to the PIPE SUPPORT.

As shown in the figure on the right, affix the insulator 

0

to the PIPE SUPPORT to sandwich it.

• After connecting the pipes and connecting cord, be sure to

screw PIPE SUPPORT tightly and fix the pipes and
connecting cord.

• Position the easy-to-attach side of PIPE SUPPORT (after

aligning it with the pipe) to face the front and secure it with
a screw. (Be sure to install PIPE SUPPORT to prevent
rodents from entering the indoor unit.)

• To prevent the pipe connector from contacting the front

cover, push the connector as far as it goes.

• Arrange the connecting cord, pipes and drain hose neatly

and store them in the bottom section of the rear surface of
the indoor unit.

Indoor unit rear surface

Pipe layout of the unit rear surface

Connecting cord

8

 Insulator

Connecting cord

Pipe

Drain hose

Pipe/drain hose layout when passing through the file in a wall

Pipe

8

 Insulator

• Sideways piping.

         Top view

Front view

Right side view

Wall

W

all

160mm or less

Floor

160mm or less

Large pipe

Small pipe

• In the case of make a hole on the wall.

Before piping

After piping

• In the case of make

a hole on the floor.

Floor

W

all

W

all

 CAUTION

When mounting the flare
insulator 

1

, make sure there

is a space between the
insulator and left of resin
part. Otherwise, may cause
water dripping.

(Unit: mm)

above 350

0

Insulator

PIPE SUPPORT

2

 Binder

1

Flare
insulator

Wrap flare insulation, bind
top and bottom flare
insulation by binder. Wrap
tape on flare insulation
closely.

2

 Binder

Pipe

Floor

32mm

3. Fixing the indoor unit

3.1 Floor installation

438

440

155

55

ø9 rear
fixing hole
for anchor
bolt or
screw of
accessory.

Fixing on the wall

Case

Fixing the base of indoor unit

• Fix the base of indoor unit on the floor with 4.1 

×

 32mm screws (right and left).

• When fixing the indoor unit above the ground, be sure to fix an L-angle at the bottom to support it.

2. Push plug into the holes.

1. Drill holes on floor.

(The plug can be secured diagonally with a screw as shown above.)

 WARNING

Be sure to attach screw 

3

 to prevent

the indoor unit from overturn.

3

 Screw (4.1x32)

Indoor unit

Plug
(Procure locally)

Screw

Screw

3

 Screw (4.1x32)

3

 Screw (4.1x32)

3

 Screw

(4.1x32)

3

 Screw

(4.1x32)

Fixing on the hanger

3.2 Wall installation

Direct mounting on the wall

184mm o

r less

Procedures of installation and precautions

Procedures to fix the hanger and indoor unit.

1. Drill holes on wall.

(As shown below)

2. Push plug into the holes.

(As shown below)

3. Fix the hanger on wall with

4.1 X 32 and 4.0 X 34 screw.
(As shown in figure below)

Wall

ø4.8mm

32mm

Wall

Plug

Hanger

3

Screw (4.1 x 32)

Horizontal air deflector (Air intake)

Above
100mm

Above 200mm

Above 150mm

Lattice door

Horizontal air deflector (Air outlet)

3.3 Built-in installation

• If outlet is covered with the lattice door, room temperature may not be

controlled properly. Therefore, air outlet must be open as much as possible.

• If air deflector of air outlet is adjusted too much upward, room temperature

may not be controlled properly due to the heat inside the lattice door.
Therefore, the deflector must be adjusted to nearly horizontal angle.

• If signal receiver is covered with the lattice door, signal receiving distance

or range (angle) becomes smaller. Therefore, signal receiver must not be
covered with the lattice door.

• Only the vertical lattice door may be used. Be sure to use a lattice door

with an open area ratio of 75% or more. If another lattice door or one with
an open area ratio of less than 75% is used, maximum performance may
not be obtained.

• With a built-in installation, it may take more time to reach the set

temperature after the unit is switched on.

30mm

Air conditioner

4.

Checking of drawing drain hose

• Connect the separate drain hose to the drain hose that is attached to the indoor unit.
• For keeping the smooth flowing of condensed water the drain hose should be inclined as shown in figure below.

Bending
upwards

Bad

Condensed
water pond

Bad

Bad

Condensed
water pond

Bad

Ditch

 CAUTION

Please ensure the smooth flow of condensed water of the Indoor unit during installation. (Carelessness may result in water
leakage.)

 WARNING

Be sure that the hose is not loosely
connected or bent.

OUTDOOR UNIT

Condensed water disposal of outdoor unit

• There is holes on the base of outdoor unit for condensed water to exhaust.
• In order to flow condensed water to the drain, the unit is installed on a stand or a block so that the unit is 100mm above

the ground as shown figure. Join the drain pipe to one hole.

• Cover the drain hole with a bush. To install the bush, put it on the drain hole as shown in the figure and press the both

sides of the bush to fit into the hole. After installation, check whether the drain pipe and bush cling to the base firmly.

• Please mount the outdoor unit on stable ground to prevent vibration and increase of noise level.

Decide the location for piping after sorting out the different types of pipe available.

When removing side cover, please pull the handle after undoing the hook by pulling it downward. Reinstall the side cover
in reverse order of the removal.

Pull downward

Please face this side (suction
side) of the unit to the wall.

Please remove side cover when
connecting the piping and connecting
cord.

=

 Bush

~

Drain pipe

Outer diameter: 16mm

Above 100mm

Base

Drain hole

RAC-25FX8 • RAC-35FX8

RAC-50FX8

~

Drain pipe

Outer diameter: 16mm

Above 100mm

Base

Drain hole

=

 Bush

• Do not touch the suction port,

bottom surface, or aluminium fin of
the outdoor unit.

• Failure to do so may cause an

injury.

 CAUTION

• Install the outdoor unit horizontally and make sure that condensate drains away.
• In case of using in cold weather area

Especially when there are heavy snows in cold weather area, condensed water freezes on the base and may not drain.
In this case, please remove the bush and the drain pipe at the bottom of the unit (left and centre near discharge portion
of air, each 1 place) to restore smooth drainage. Ensure that the distance from the drain hole to the ground is 250mm or
more.

• Remove PIPE SUPPORT.
• Insert the drain hose into the hole in the wall.
• Winding insulation pipe for drain hose and taping 4 or 5 places to fix.
• Connect the pipe to the Indoor unit.
• After completing the piping connection, cover the connector with the insulator.
• Connect the cord (follow instructions in the section “Connection of the connecting cord” on the reverse of this sheet).

ø4.8mm

Direction of Piping

Piping configuration may be in three
different directions: direct rear piping,
right downward piping and right
sideways piping.

Figure showing the installation of Indoor and Outdoor Unit.

(For example: Wall installation)

• The refrigerating machine oil is easily affected by moisture. Use

caution to prevent water from entering the cycle.

• The difference in height between the indoor and outdoor unit should

be kept below 10m.

• The connecting pipe, no matter big or small, should all be insulated

with insulation pipe and then wrapped with vinyl tape. (The insulator
will deteriorate if it is not wrapped with tape.)

The connection of insulated drain hose.

Please use insulated drain hose for the
indoor piping (commercial product).

above 200mm

 above 50mm

 give clearance as

wide as possible

 above 200mm

above 100mm

above 200mm

The indoor piping should be
insulated with the enclosed
insulation pipe. (If the insulator is
insufficient, please use commercial

products.)

Above 100mm

Above 150mm

Above

200mm

-

 Bush

When mounting on a wall
(up to 150~500mm from
the floor surface)

Be sure to completely
seal any gap with putty.

The space indicated by an arrow 

 is to

guarantee the performance of the air
conditioner. install the apparatus at the
ample space in order to carry out the
maintenance and repair works.

Maximum pipe length 30m

RAF-50FX8/RAC-50FX8

Above 100mm

Above 150mm

Above

200mm

The space indicated by an arrow 

  is to

guarantee the performance of the air
conditioner. install the apparatus at the ample
space in order to carry out the maintenance
and repair works.

The indoor piping should be
insulated with the enclosed
insulation pipe. (If the insulator
is insufficient, please use
commercial products.)

-

 Bush

When mounting on a wall
(up to 150~500mm from
the floor surface)

Be sure to com-
pletely seal any
gap with putty.

Maximum pipe leng

th 20m

above 200mm

(

)

above 50 mm when
installed on the
ceiling of balcony

above 100mm

above 200mm

 above 50mm

 give clearance as

wide as possible

RAF-25FX8/RAC-25FX8
RAF-35FX8/RAC-35FX8

 above 300mm

Inner diameter ø16mm

(

)

above 50 mm when
installed on the
ceiling of balcony

• The refrigerating machine oil is easily affected by moisture. Use

caution to prevent water from entering the cycle.

• The difference in height between the indoor and outdoor unit should

be kept below 10m.

• The connecting pipe, no matter big or small, should all be insulated

with insulation pipe and then wrapped with vinyl tape. (The insulator
will deteriorate if it is not wrapped with tape.)

The connection of insulated drain hose.

Please use insulated drain hose for the
indoor piping (commercial product).

Inner diameter ø16mm

No.

Item

Qty

1

Flare Insulator

1

2

Binder

2

3

Screw for Overturn

Prevention

8

                       (4.1 

×

 32)

4

Holder for Remote

Controller

1

5

Screw for Holder of
Remote Controller

2

                       (3.1 

×

 16)

6

AAA size
Battery

2

Dimension of Mounting Stand of

the Outdoor Unit

(unit : mm)

Mounting Stand

Signal receiver

Hanger

Hole for pipe

Level

Line

Weight

Screw for Hanger

Please use more
than 6 screws

Mark

External dimension of

indoor unit

20mm

750mm

50mm

470mm

Drain Hose

20mm

55mm

Please remove 3 screws and clip
which fix to the stand and cabinet.
(As shown in the figure below)

Please remove the screws which fix the cabinet and hanger.

Please use hidden beams in the wall to hold the hanger.

@

 Sheet

@

 Sheet

1. Drill holes on wall.

(As shown below)

2. Push plug into the

holes.
(As shown below)

Wall

ø4.8mm

32mm

Wall

Plug

3

 Screw

(4.1 x 32)

For outdoor unit installation, allow at least 2 sides of
space around the unit to ensure ventilation flue.

For outdoor unit installation, allow at least 2 sides of
space around the unit to ensure ventilation flue.

Screw (2 pieces)

9

Screw

(4.0 x 34)

9

Screw

(4.0 x 34)

3

Screw

(4.1 x 32)

3

Screw

(4.1 x 32)

4. Fix the indoor unit on the wall

with 4.1 X 32 screw.

Cabinet

3

Screw
(4.1x32)

 CAUTION

The draining of the water container inside the Indoor unit can be done from the left. Therefore the hanger must be fixed
horizontally or slightly tilted towards the side of drain hose. Otherwise, condensed water may overflow the water container.

No.

Item

Qty

=

Bush

1

 (2 pcs for RAC-50FX8 )

~

Drain Pipe

1

!

Purifying Filter

1

@

Sheet

3

The components of 

=

 & 

~

 are included

in the package of the outdoor unit.

330

310

(10)

10

500

35

50

12

125

(2

 

pcs

 

for

 

RAC-50FXA

 

)

Plug
(Procure

 

locally)

RAF-50PXA/RAC-50FXA

RAF-25PXA/RAC-25FXA
RAF-35PXA/RAC-35FXA

RAC-25FXA

 

s

 

RAC-35FXA

RAC-50FXA

Plug
(Procure

 

locally)

7

4

6

5

<

 

S885

 

:

   

>

1

H

anger

16

7

4

6

5

Minimum pipe length 3m

Minimum pipe length 3m

B

Reviews: