– 2 –
Metal plate
(of Al. stainless steel, etc.)
Working table
Resistor 1M
Ω
(1/2W)
Earth wire
Staple
Bare copper wire
(for body earth)
Fig. 3 Grounding of the working table
(6) Use a three wire type soldering iron including a grounding wire.
Use a high insulation mode (100V, 10M
Ω
or higher) when ordinary iron is to be used.
(7) In checking circuits for maintenance, inspection, or some others, be careful not to have the test probes
of the measuring instrument shortcircuit a load circuit or the like.
Soldering iron
Grounding wire
Screw stop at the screwed
part using a rag plate
Fig. 4 Grounding a solder iron
➤