– 105 –
[No operation or abnormal operation]
Is AC220-240V
being
supplied to terminal L and N?
Is the 25A
fuse normal?
If the 25A fuse has blown, be aware
that other parts may also be
defective (mainly
, varistor 2, diode
stack, smoothing capacitors, system
power module, etc.).
No
Ye
s
CHECKING THE OUTDOOR UNIT ELECTRICAL PARTS
Replace any defective parts.
Is the power circuit normal?
See the description on
power circuit for details.
Is 5V being generated
between Pin
4
(0V) and pin
3
(5V) at CN 18 (test pin)?
Operate the outdoor unit
according to the instruction
“How to operate the outdoor
unit independently
”.
How did the self-diagnosis
lamp (LD301) light?
Is the switching power circuit OK?
Has the 3A fuse blown?
See the self-diagnosis lamp
lighting mode.
Check to see whether the
connected C and D cable
correctly? If reversed, correct the
cable connection.
Replace any defective parts.
If the 3A fuse has blown, the
switching transformer (T1),
R906, etc. may also be
defective.
()
No
Ye
s
Ye
s
No
Ye
s
Summary of Contents for RAC-65NH5
Page 36: ...CIRCUIT DIAGRAM 37 ...
Page 37: ...CIRCUIT DIAGRAM MODEL RAC 65NH5 39 ...
Page 87: ... 99 SELF DIAGNOSIS LIGHTING MODE ...
Page 89: ... 101 2 Outdoor unit does not operate but receives remote infrared signal ...
Page 91: ... 103 6 Check the main P W B power circuit ...
Page 92: ... 104 CHECKING THE REMOTE CONTROLLER ...
Page 97: ... 109 ...
Page 107: ...HITACHI PM NO 0000E Printed in Malaysia RAK 65NH5 RAC 65NH5 ...