– 26 –
INFO FUNCTION
●
By
pressing
(INFO) button, temperature around remote controller and monthly power consumption will
be displayed on the remote controller.
●
After changing the batteries, direct the remote controller towards the indoor unit and press
(INFO) button.
Current calendar and clock will be transmitted from indoor unit.
●
In order to receive information from indoor unit, the distance between remote controller and receiver of indoor
units is within 2 meters.
■
To check temperature around remote controller
■
Current calendar and clock can be retrieved from indoor unit
■
To check monthly power consumption
Press
(INFO) button.
Temperature will be displayed for 10 seconds.
Direct the remote controller towards the receiver of indoor unit (within 2 meters
in front of indoor unit) and press
(INFO) button. Wait for 2 seconds for
signal transmission.
Once received the current calendar and clock, check whether they are correct
or not by pressing
(CLOCK) button.
●
If there is no power supply to indoor unit or calendar and clock have not been
set, INFO function cannot be used for sending or receiving information.
Direct the remote controller towards the receiver of indoor unit (within 2 meters
in front of indoor unit) and press
(INFO) button. Wait for 2 seconds for
signal transmission.
While temperature around remote controller is displayed, press
(INFO)
button repeatedly. The display will show as below:
this month power consumption amount for heating
last month power consumption
amount for heating
this month power consumption amount for cooling
last
month power consumption amount for cooling
temperature around remote
controller
this month power consumption amount for heating ...... cyclically.
●
If indication is not given, bring remote controller closer to the receiver of
the indoor unit.
●
Indicated value shall be regarded as a guide only.
NOTE
●
In case failure occurs to the air conditioner, by pressing
(INFO) button, an error code will be displayed.
Direct the remote controller towards the receiver of indoor unit (within 2 meters in front of indoor unit)
and press
(INFO) button. Wait for 2 seconds for signal transmission.
An error code will be displayed.
Call service center and inform the error code.
●
Information of "Monthly power consumption" is not available for 6 rooms multi system.
●
Info Function to check monthly power consumption.
During installation, in case of power failure or breaker ON / OFF, ensure to set the clock and calendar for each
indoor unit (unit in standby mode or auto restart), for single or multi connection, by pressing
(START / STOP)
button.
Failure to do the above,monthly power consumption amount will not be displayed on the remote controller.