The application manual contains application descriptions and setting guidelines sorted per function.
The manual can be used to find out when and for what purpose a typical protection function can be
used. The manual can also provide assistance for calculating settings.
The technical manual contains operation principle descriptions, and lists function blocks, logic
diagrams, input and output signals, setting parameters and technical data, sorted per function. The
manual can be used as a technical reference during the engineering phase, installation and
commissioning phase, and during normal service.
The communication protocol manual describes the communication protocols supported by the IED.
The manual concentrates on the vendor-specific implementations.
The point list manual describes the outlook and properties of the data points specific to the IED. The
manual should be used in conjunction with the corresponding communication protocol manual.
The cyber security deployment guideline describes the process for handling cyber security when
communicating with the IED. Certification, Authorization with role based access control, and product
engineering for cyber security related events are described and sorted by function. The guideline can
be used as a technical reference during the engineering phase, installation and commissioning
phase, and during normal service.
1.3.2
Document revision history
GUID-34B323E4-1319-4D42-80CE-29B0F2D36E2C v7
Document
revision
Date
Product version
History
-
2017-05
First release for product version 2.2
A
2017-10
Ethernet ports with RJ45 connector added. enhancements/
updates made to ZMFPDIS and ZMFCPDIS.
B
2018-03
Document enhancements and corrections
C
2018–06
LDCM galvanic X.21 added. Function PTRSTHR added.
Ordering section updated.
D
2018–11
Functions CHMMHAI, VHMMHAI, DELVSPVC, DELSPVC
and DELISPVC added. Updates/enhancements made to
HZPDIF, CCRBRF, REALCOMP, PTRSTHR and FNKEYMDx.
Ordering section updated.
E
2019-05
PTP enhancements and corrections
F
Document not released
G
Document not released
H
Document not released
J
2020-09
Functions APPTEF, SCCFPVOC, SCUCPTOC, SCPDPTOV,
SCUVPTOV, IEC 61850SIM and ALGOS added. Updates/
enhancements made to functions ZCVPSOF, EF4PTOC,
ROV2PTOV, SAPTUF, SAPTOF, CCSSPVC, FUFSPVC,
SESRSYN, SMPPTRC, SSIMG, and SSIML.
K
2021-06
Functions FLTMMXU, BRPTOC, LMBRFLO, HOLDMINMAX,
INT_REAL, CONST_INT, INTSEL, LIMITER, ABS, POL_REC,
RAD_DEG, CONST_REAL, REALSEL, STOREINT,
STOREREAL, DEG_RAD and RSTP added. Updates/
enhancements made to functions STBPTOC, EF4PTOC,
CHMMHAI, VHMMHAI, OC4PTOC, NS4PTOC, CVGAPC,
DRPRDRE, SXSWI and SXCBR.
L
2022-07
2.2.5.4
Introduced RIA600, which is a software implementation of the
IED LHMI panel.
1MRK 511 403-UEN Rev. L
Section 1
Introduction
Bay control REC670
13
Commissioning manual
© 2017 - 2022 Hitachi Energy. All rights reserved
Summary of Contents for REC670
Page 1: ...Relion 670 SERIES Bay control REC670 Version 2 2 IEC Commissioning manual ...
Page 2: ......
Page 28: ...22 ...
Page 54: ...48 ...
Page 60: ...54 ...
Page 66: ...60 ...
Page 90: ...84 ...
Page 212: ...206 ...
Page 218: ...212 ...
Page 232: ...226 ...
Page 240: ...234 ...
Page 241: ...235 ...