217
Failure diagnosis method
SMGB0066 rev.0 - 12/2009
Troubleshooting
Service Manual
7
Voltage test position:
VCC05
IC6
IC7
IC4
C70
C72
C71
C22
C3
8
7
6
5
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
DSW2
DSW4
VCC24
GND1
VCC05
VCC12T
VCC12
GND2
VCC24N
VCC05T
DSW3
DSW1
DSW5
4
3
2
1
DSW7
4
3
2
1
DSW9
4
3
2
1
DSW8
4
3
2
1
PSW1
PSW2
LED8
LED7
JP1
Z3
Z2
C3
C111
C5
C4
IC1
C28
C33
C31
C38
OSC
C21
EF1
C36
C19
DM5
DM2
DM1
DM4
DM3
REG3
CN6
PCN3
B
PCN3A
CN10
B
CN10A
PCN2
CN5
CN4
CN3
CN1
CN8
CN14
CN15
CN2
CN9
CN7A
CN7B
IC8
IC3
DSW6
2
1
Z5 Z6
C62
C68
C7
R81
D6 D7
D1
L1
C20
C2
C1
REG2
REG4
REG1
REG
5
REG
7
VCC24N
GND2
GND1
VCC24/VCC05T VCC12
VCC12T
Inicialization procedure
Power Supply OFF, and set DSW1-1, DSW5-2,3 ON,
and DSW 5-1,4 OFF on PCB
(Record original DIP switch setting)
Power Supply ON, and confirm segment shows as follows:
<Initialization successfully done>
If segment shows as follows, Power Supply OFF once, and Power ON again:
<Initialization failure>
If segment shows as "Initialization Successfully Done", Initialization Succeed. Power Supply OFF, and DSW1-1, DSW5-
2,3 set original setting again. Initialization is finished. In other case, if segment shows nothing even if doing Initialization
procedure, or shown Initialization Failure, PCB1 is broken and replace PCB1.