Troubleshooting
Service Manual
218
Checking procedure for main parts
SMGB0066 rev.0 - 12/2009
DIP-IPM
Connecting Wires
Electrical
soldering iron
Plug
7.4. CHECKInG ProCEdUrE for MAIn PArTS
7.4.1. rHUE-(3~6)AVHn. Procedure for checking the dIP-IPM.
High voltage discharge is an imperative work for replacing
parts.
warning
Electrical hazard. Risk of electrical shock. Perform this high
-
voltage discharge work to avoid an electric shock.
Turn OFF the main switches and wait for three
1.
minutes. Make sure that no high voltage exists. If
LED201 is ON after start-up and LED201 is OFF after
turning OFF power source, the voltage will decrease
lower than DC50V.
Connect connecting wires to an electrical soldering iron
2.
Connect the wires to terminals, P and N on DIP-IPM.
3.
=> Discharging is started, resulting in hot soldering
iron. Pay attention not to short-circuit between terminal
P(+) and N(-)
Wait for 2 or 3 minutes and measure the voltage once
4.
again. Check to ensure that no voltage is charged.
● Inverter module checking procedure
Internal circuit of rectified part of DIP-IPM
Non-faulty if [1] – [8] are checked and satisfied. (Measure
with 1 kΩ range of a tester.)
note
DO NOT use a digital tester.
-
Touch [+] of the tester to DIP-IPM 52C terminal, and [-]
1.
to DIP-IPM R, S terminals to measure the resistance.
Normal if all three terminals have 1 kΩ or greater.
Contrary to [1], touch [-] of the tester to DIP-IPM 52C
2.
terminal, and [+] to DIP-IPM R, S terminals to measure
the resistance.
Normal if all three terminals have 100 kΩ or greater.
Touch [-] of the tester to [-] of DIP-IPM DMI (soldered
3.
part), and [+] of the tester to DIP-IPM R, S terminals to
measure the resistance.
Normal if all three terminals have 1 kΩ or greater
Contrary to [3], touch [+] of the tester to [-] of DIP-IPM
4.
DMI, and [-] of the tester to DIP-IPM R, S terminals to
measure the resistance. Normal if all three terminals
have 100 kΩ or greater.
Contact with specified terminals
to measure.
Tester