Controller pack
Service Manual
74
System configuration, settings and control system
SMGB0066 rev.0 - 12/2009
4.1.3. Contents of the controller pack
System Controller
System Controller
- System Controller
• Controls the heat pump.
• Controls other system components.
• Measures system sensors.
• Allows system configuration and settings.
Room Unit
RF Receiver
System MMI Pack
- System MMI Pack
• Room Unit - The user interface for the system and
allows time / temperature profile programming.
• RF Receiver - Receives wireless signals from the Room
Unit and is wired directly to the System Controller.
Water Temperature
Sensors
Outside
Temperature
Sensor
Sensor Pack
- Sensor Pack
• 3 x Water Temperature Sensors.
• 1 x Outside Temperature Sensor.
• Sensors connect directly to System Controller.
4.1.4. Quick-start installation steps
Select which type of system you wish to install.
1.
Determine where the various system components should be installed.
2.
Mount the system components- for System Controller and Sensors: see installation instructions in the System MMI
3.
Pack.
Connect the Sensors, RF Receiver, heat pump and other system components to the System Controller according to
4.
your selected system configuration.
Change installer parameters on the System Controller according to your selected system configuration.
5.
Review settings and time/temperature profile on the Room Unit (see installation instructions in the System MMI Pack).
6.
Test the system.
7.
Show end-user how to operate the Room Unit.
8.
Leave literature pack with the end-user.
9.