7. Wiring
7-17
(2) When using the HSC-1000 series remote I/O station (RI/O: LQS010) together with the HSC-2100 series
remote I/O station (E.STATION: LWS410)
Like the S10V, the S10VE can connect to HSC-1000 series and HSC-2100 series remote I/O stations.
The S10VE can also connect to the remote I/O stations designed for common use by the S10V and
S10mini. Figure 7-17 shows a wiring example for these scenarios.
- For details on how to set the terminating resistance, see
7.7.4 Setting terminating resistance
.
- For details on ground wiring, see
7.4 Ground wiring
.
Figure 7-17 Wiring example when using HSC-1000 and HSC-2100 series remote I/O stations
in the same system
LQS010
RI/O
HITACHI
HSC-1000
RI/O
ST.NO
U
L
FIX
COM
HOLD
RI/
01A
RI/
01B
SHD
150
Ω
COM
100
Ω
128M
64M
32M
RI/
02A
COM
RI/
02B
SHD
FG
NC
LQE950
RI/O-IF
RI/O
STOP
STOP
/RUN
SHD
PCsOK
100VAC
100VDC
SHD
SHD
TERM
150Ω
TERM
100Ω
SHD
FG
L
A
B
100VAC
100VDC
TERM
150Ω
TERM
100Ω
A
B
RI/O1
RI/O2
L
Remote I/O station module
(150Ω termination)
RI/O-IF module
(RI/O-
1: 100Ω termination)
(RI/O-
2: 150Ω termination)
100Ω termination
■ RI/O-1
Max. 100 m of remote I/O cabling
(CO-SPEV-SB(A) 1P × 0.3SQ LF)
100Ω
■ RI/O-2
Max. 200 m of remote I/O
cabling
(CO-EV-SB 1P × 0.18SQ LF)
150Ω
150Ω (B4)
RI/O2A (B6)
RI/O2B (B7)
SHD (B8)
100Ω (A6)
RI/O1A (A7)
RI/O1B (A8)
SHD (A9)
HSC-2100
Remote I/O station module
(not terminated)
RI/O OUT-A (4)
RI/O OUT-B (5)
SHD (6)
HSC-2100
Remote I/O station module
(external 100Ω termination)
150Ω termination
RI/O IN-A (1)
RI/O IN-B (2)
SHD (3)
To terminate with
100Ω, connect an
external resistor to the
RI/O OUT terminal.
RI/O OUT-A (1)
RI/O OUT-B (2)
RI/O IN-A (1)
RI/O IN-B (2)
SHD (3)
Do not use the built-
in 150Ω
terminating resistor.
TERM TA (7)
TERM TB (8)
100Ω
LWS410
RI/O
STNO
U
L
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
RI/O
ON
A
B
SHD
RI/O
OUT
A
B
SHD
TERM
TA
TB
SHD
FOX
S0
C0
OUTPUT
HOLD
S1
126P
S2
64P
S3
32P
S4
S1
S2
S3
S4
E.STATION
HITACHI
LWS410
RI/O
STNO
U
L
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
RI/O
ON
A
B
SHD
RI/O
OUT
A
B
SHD
TERM
TA
TB
SHD
FOX
S0
C0
OUTPUT
HOLD
S1
126P
S2
64P
S3
32P
S4
S1
S2
S3
S4
E.STATION
HITACHI
RI/O1A (A4)
RI/O1B (A5)
SHD (A6)
150Ω (A7)
COM (A8)
150Ω termination
Note: For the actual RI/O-IF module and remote I/O station module, except
for the HSC-2100 remote I/O station module (LWS410), cables
cannot be attached on the terminal block from the right side.
The following figure shows cables attached from the right to make
the wiring easier to understand.
Summary of Contents for S10VE
Page 1: ...User s Manual General Description SEE 1 001 A ...
Page 2: ...User s Manual General Description ...
Page 53: ...This page is intentionally left blank ...
Page 59: ...This page is intentionally left blank ...
Page 67: ...This page is intentionally left blank ...
Page 75: ...This page is intentionally left blank ...
Page 77: ...This page is intentionally left blank ...
Page 103: ...This page is intentionally left blank ...
Page 129: ...This page is intentionally left blank ...
Page 295: ...This page is intentionally left blank ...
Page 309: ...This page is intentionally left blank ...
Page 341: ...This page is intentionally left blank ...
Page 345: ...This page is intentionally left blank ...
Page 475: ...This page is intentionally left blank ...
Page 489: ...This page is intentionally left blank ...
Page 505: ......