background image

11

AB

C

D

1-1

953230

1

”2, 3”

1-2

953268Z

1

”2, 3”

 ”A

UT”

2-1

958900

2

2-2

981586

2

”A

UT”

3A

961681

2

M4 × 5

4-1

953231C

1

110V

-120V ”5”

4-2

953231L

1

220V

-230V ”5”

 ”EUR

OPE”

4-3

953231M

1

220V

-230V ”5”

 ”IT

A, HOL, 

SWE, A

UT”

4-4

953231J

1

220V

-230V ”5”

 ”NZL

4-5

953231K

1

220V

-230V ”5”

 ”S

AF”

4-6

953231F

1

240V ”5”

4-7

953231H

1

240V ”5”

 ”A

US”

5

930703

2

6

949233

2

M5 × 55

7

949454

2

M

5

8

949555

2

M

5

9

953232

2

10

931701

1

11A-1

953297C

1

110V

-120V ”12, 15A, 70”

11A-2

953297E

1

220V

-230V ”12, 15A, 70”

11A-3

953297F

1

240V ”12, 15A, 70”

12

608VVM

1

608VV

C2P

S2L

13

953234

1

”14”

14

937033

1

15A

6002VV

1

6002VV

CMP

S2L

16

953235

1

17

953236

1

18

949217

6

M4 × 12

19

949453

6

M

4

20

953237

1

21

6200VV

1

6200VV

CMP

S2L

22

953238Z

1

23

940533

1

3 × 3 × 10

24

6202VV

1

6202VV

CMP

S2L

25

938403

1

26

937077

1

27

953239

1

28

953240

2

29

953241

1

30

949239

4

M5 × 16

31

949454

4

M

5

32

937807

8

D5 × 25

33

949424

4

M

5

34

949454

8

M

5

35

999043

2

36-1

945161

2

36-2

961781

2

”A

UT”

38

–––––––––––

1

AB

C

D

39-1

958049

1

D8.2

39-2

940778

1

D8.2

40

937631

1

41

954017

2

D4 × 12

42-1

986201

1

42-2

931573

1

”HOL, A

UT”

42A

956632

1

”A

U

S,

 GBR, FR

G, FRA, 

ESP

, SUI”

43

953261

1

44-1

956613

1

100V

-127V

44-2

957556

1

220V

-240V

44-3

990373

1

”A

US”

45-1

953243

1

45-2

–––––––––––

1

”NZL, IT

A”

46A

994273

1

47A

981010

1

48

959140

1

49

959141

1

51A

984750

2

D4 × 16

52

949423

3

M

4

53

957561

1

54

949509

2

D2.5 × 3.2

55

–––––––––––

1

56

953246Z

1

M14

57

953247Z

1

58A

314086

2

180MM C-P24

59A

314087

2

180MM C-P30

60A

314090

2

180MM C-P50

61A

314092

2

180MM C-P80

62A

314094

2

180MM C-P120

63

949103

1

180MM

64

956633

1

65A

936638

1

17MM

66

937913Z

1

68

949440

2

M3.5 ”A

US”

69

956384

3

D4 × 20

70

956387

1

71

971792

1

72

953260

1

”71, 79, 80”

73-1

958263

1

73-2

953298

1

”EUR

OPE”

74

953265

1

75

938307

1

76

980063

1

77

981373

2

78

983684

1

79

953258

1

80

953259

1

000Book̲SAT-180.indb   11

000Book̲SAT-180.indb   11

2015/06/11   14:50:28

2015/06/11   14:50:28

Summary of Contents for S920

Page 1: ...Sander Polisher SAT 180 Handling instructions Read through carefully and understand these instructions before use 000Book SAT 180 indb 1 000Book SAT 180 indb 1 2015 06 11 14 50 26 2015 06 11 14 50 26 ...

Page 2: ... ﻗﺭﺹ 3 Rubber pad ﻣﻁﺎﻁﻳﺔ ﻭﺳﺎﺩﺓ 4 Spindle ﺍﻟﺩﻭﺭﺍﻥ ﻋﻣﻭﺩ 5 Wrench A A ﺍﻟﺭﺑﻁ ﻣﻔﺗﺎﺡ 6 Hood ﺍﻟﻣﺣﺭﻙ ﻏﻁﺎء 7 Tuck the excess string in into ﺑﺎﻟﺩﺍﺧﻝ ﺍﻟﺯﺍﺋﺩﺓ ﺍﻟﺣﻠﻘﺔ ﺑﻁﻲ ﻗﻡ 8 Wear limit ﺍﻟﺗﺂﻛﻝ ﺣﺩ 9 No of carbon brush ﺑﺎﻟﻛﺭﺑﻭﻥ ﺍﻟﺻﻘﻝ ﻓﺭﺷﺎﺓ ﺭﻗﻡ 000Book SAT 180 indb 2 000Book SAT 180 indb 2 2015 06 11 14 50 27 2015 06 11 14 50 27 ...

Page 3: ...e tool Carrying power tools with your finger on the switch or energising power tools that have the switch on invites accidents d Remove any adjusting key or wrench before turning the power tool on A wrench or a key left attached to a rotating part of the power tool may result in personal injury e Do not overreach Keep proper footing and balance at all times This enables better control of the power...

Page 4: ...en performing an operation where the cutting accessory may contact hidden wiring or its own cord Cutting accessory contacting a live wire may make exposed metal parts of the power tool live and could give the operator an electric shock k Position the cord clear of the spinning accessory If you lose control the cord may be cut or snagged and your hand or arm may be pulled into the spinning accessor...

Page 5: ...te on product as it is subject to change by areas PRIOR TO OPERATION 1 Power source Ensure that the power source to be utilized conforms to the power requirements specified on the product nameplate 2 Power switch Ensure that the power switch is in the OFF position If the plug is connected to a receptacle while the power switch is in the ON position the power tool will start operating immediately w...

Page 6: ...pindle Ensure that the washer nut is thoroughly tightened by using both wrench A and B 3 As shown in Fig 4 wrap the rubber pad with the hood of the wool bonnet and firmly secure it by tightening and tying its draw string Be sure the excess string is firmly tucked inside the wool bonnet to prevent it from flying out while polishing CAUTION Improper fitting of the wool bonnet may cause vibration 4 T...

Page 7: ... ﺍﻷﺟﺯﺍء ﻣﻥ ﻭﻫﻲ ﺍﻟﻛﺭﺑﻭﻧﻳﺔ ﺍﻟﻔﺭﺷﺎﺓ ﺍﻟﻣﺣﺭﻙ ﻳﺳﺗﻬﻠﻙ ﺑﺎﻟﻣﺣﺭﻙ ﻣﺷﺎﻛﻝ ﻭﺟﻭﺩ ﻋﻧﻪ ﻳﻧﺗﺞ ﻗﺩ ﺍﻟﻛﺭﺑﻭﻧﻳﺔ ﺍﻟﻔﺭﺷﺎﺓ ﺗﺂﻛﻝ ﻷﻥ ﺍ ً ﻧﻅﺭ ﺍﻟﻔﺭﺷﺎﺓ ﺭﻗﻡ ﻧﻔﺱ ﻟﺩﻳﻬﺎ ﺟﺩﻳﺩﺓ ﺑﺄﺧﺭﻯ ﺍﻟﻛﺭﺑﻭﻧﻳﺔ ﺍﻟﻔﺭﺷﺎﺓ ﺑﺎﺳﺗﺑﺩﺍﻝ ﻗﻡ ﺣﺩ ﻣﻥ ﺍﻗﺗﺭﺍﺑﻬﺎ ﺃﻭ ﺗﺂﻛﻠﻬﺎ ﻋﻧﺩ ﺍﻟﺷﻛﻝ ﻓﻲ ﻣﻭﺿﺢ ﻫﻭ ﻛﻣﺎ ﺍﻟﻛﺭﺑﻭﻧﻳﺔ ﺑﺎﺳﺗﻣﺭﺍﺭ ﺍﻟﻛﺭﺑﻭﻧﻳﺔ ﺍﻟﻔﺭﺷﺎﺓ ﺑﺗﻧﻅﻳﻑ ﻗﻡ ﺫﻟﻙ ﺇﻟﻰ ﺑﺎﻹﺿﺎﻓﺔ ﺍﻟﺗﺂﻛﻝ ﺍﻟﻔﺭﺷﺎﺓ ﻣﻘﺎﺑﺽ ﺩﺍﺧﻝ ﺑﺳﻼﺳﺔ ﺍﻧﺯﻻﻗﻬﺎ ﻣﻥ ﻭﺍﻟﺗﺄﻛﺩ ﺍﻟﻛﺭﺑﻭﻧﻳﺔ ﺍﻟﻔﺭﺷﺎﺓ ﺍﺳﺗﺑﺩﺍﻝ 3 ﺃﻏﻁﻳﺔ ﻟﻔﻙ ﻓﺗﺣﺎﺕ ﺫﻭ ﻣﻔﻙ ﺍﺳﺗﺧﺩﺍﻡ ﺍ...

Page 8: ...ﺍﻻﺳﻡ ﻟﻭﺣﺔ ﻋﻠﻰ ﺍﻟﻣﺣﺩﺩﺓ ﺍﻟﻁﺎﻗﺔ ﺍﻟﻁﺎﻗﺔ ﻣﻔﺗﺎﺡ 2 ﺍﻟﻘﺎﺑﺱ ﺗﻭﺻﻳﻝ ﺣﺎﻟﺔ ﻓﻲ ﺇﻳﻘﺎﻑ ﺍﻟﻭﺿﻊ ﻋﻠﻰ ﺍﻟﻁﺎﻗﺔ ﻣﻔﺗﺎﺡ ﺃﻥ ﻣﻥ ﺗﺄﻛﺩ ﺃﺩﺍﺓ ﺗﺷﻐﻳﻝ ﻓﺳﻳﺗﻡ ﺗﺷﻐﻳﻝ ﺍﻟﻭﺿﻊ ﻋﻠﻰ ﺍﻟﻁﺎﻗﺔ ﻣﻔﺗﺎﺡ ﻭﻛﺎﻥ ﺑﺎﻟﻣﻘﺑﺱ ﺧﻁﻳﺭ ﺣﺎﺩﺙ ﻭﻗﻭﻉ ﺇﻟﻰ ﻳﺅﺩﻱ ﻗﺩ ﻣﻣﺎ ﺍﻟﻔﻭﺭ ﻋﻠﻰ ﺍﻟﻁﺎﻗﺔ ﺍﻹﺿﺎﻓﻲ ﺍﻟﺗﻭﺻﻳﻝ ﺳﻠﻙ 3 ﺗﻭﺻﻳﻝ ﺳﻠﻙ ﺍﺳﺗﺧﺩﻡ ﺍﻟﻁﺎﻗﺔ ﻣﺻﺩﺭ ﻣﻥ ﺍﻟﻌﻣﻝ ﻣﻧﻁﻘﺔ ﺇﺯﺍﻟﺔ ﻋﻧﺩ ﺍﻟﺗﻭﺻﻳﻝ ﺳﻠﻙ ﻳﻅﻝ ﺃﻥ ﻳﺟﺏ ﻣﻘﻧﻧﺔ ﻭﺳﻌﺔ ٍ ﻑ ﻛﺎ ﺳﻣﻙ ﺫﻭ ﺇﺿﺎﻓﻲ ﺍﻟﻣﺳﺗﻁﺎﻉ ﺑﻘﺩﺭ ﺍ ً ﻗﺻﻳﺭ ﺍﻹﺿﺎﻓﻲ ﺍﻟﻌﻣﻠﻳﺔ ﺍﻟﻣﻠﻣﻊ ﺳﺎﻧﺩﺭ ﺃﺩﺍﺓ ﺍﺳﺗ...

Page 9: ... ﻭﺫﺭﺍﻋﻙ ﻳﺩﻙ ﺳﺣﺏ ﻭﻳﺗﻡ ﻳﺗﻣﺯﻕ ﺃﻭ ﺍﻟﺳﻠﻙ ﻳﻧﻘﻁﻊ ﻓﻘﺩ ﺍﻟﺗﺣﻛﻡ ﻓﻘﺩﺕ ﺇﺫﺍ ﺍﻟﺩﻭﺭﺍﻥ ﻣﻠﺣﻕ ﺇﻟﻰ ًﺎ ﻣ ﺗﻣﺎ ﺍﻟﻣﻠﺣﻕ ﻳﺗﻭﻗﻑ ﺣﺗﻰ ﻷﺳﻔﻝ ﺍﻟﻁﺎﻗﺔ ﺃﺩﺍﺓ ًﺍ ﺩ ﺃﺑ ﺗﺿﻊ ﻻ ﺱ ﺍﻟﺗﺣﻛﻡ ﻋﻥ ﺍﻟﻁﺎﻗﺔ ﺃﺩﺍﺓ ﻭﻳﺧﺭﺝ ﺑﺎﻟﺳﻁﺢ ﺍﻟﺩﻭﺭﺍﻥ ﻣﻠﺣﻕ ﻳﻣﺳﻙ ﻗﺩ ﺟﺎﻧﺑﻙ ﻋﻠﻰ ﺣﻣﻠﻬﺎ ﺃﺛﻧﺎء ﺍﻟﻁﺎﻗﺔ ﺃﺩﺍﺓ ﺗﺷﻐﻳﻝ ﻋﻠﻰ ﺗﻌﻣﻝ ﻻ ﺵ ﻣﻣﺎ ﻣﻼﺑﺳﻙ ﻗﻁﻊ ﻓﻲ ﺍﻟﺩﻭﺭﺍﻥ ﻟﻣﻠﺣﻕ ﺍﻟﻣﻔﺎﺟﺊ ﺍﻟﻠﻣﺱ ﻳﺗﺳﺑﺏ ﻓﻘﺩ ﺟﺳﻣﻙ ﺍﺗﺟﺎﻩ ﻓﻲ ﺍﻟﻣﻠﺣﻕ ﻳﺳﺣﺏ ﺑﺎﺳﺗﻣﺭﺍﺭ ﺍﻟﻁﺎﻗﺔ ﺑﺄﺩﺍﺓ ﺍﻟﺗﻬﻭﻳﺔ ﺟﺯء ﺑﺗﻧﻅﻳﻑ ﻗﻡ ﺹ ﺍﻷﺗﺭﺑﺔ ﺗﺭﺍﻛﻡ ﺯﻳﺎﺩﺓ ﺗﺗﺳﺑﺏ ﻭ...

Page 10: ...ﺣﻣﻝ ﺃﻭ ﻭﺍﻻﻟﺗﻘﺎﻁ ﺍﻟﺑﻁﺎﺭﻳﺔ ﺃﻭ ﺍﻟﻣﻔﺗﺎﺡ ﻓﻲ ﺇﺻﺑﻌﻙ ﻭﺟﻭﺩ ﻣﻊ ﺍﻟﻛﻬﺭﺑﺎﺋﻳﺔ ﺍﻟﻌﺩﺩ ﺣﻣﻝ ﻳﺅﺩﻱ ﺍﻟﺗﺷﻐﻳﻝ ﻭﺿﻊ ﻓﻲ ﺍﻟﻣﻔﺗﺎﺡ ﻓﻳﻬﺎ ﻳﻛﻭﻥ ﺍﻟﺗﻲ ﺍﻟﻛﻬﺭﺑﺎﺋﻳﺔ ﺍﻟﻌﺩﺩ ﺗﺷﻐﻳﻝ ﺣﻭﺍﺩﺙ ﻭﻗﻭﻉ ﺍﺣﺗﻣﺎﻝ ﺇﻟﻰ ﺍﻟﻛﻬﺭﺑﺎﺋﻳﺔ ﺍﻟﻌﺩﺓ ﺗﺷﻐﻳﻝ ﻗﺑﻝ ﺍﻟﺭﺑﻁ ﻣﻔﺗﺎﺡ ﺃﻭ ﺍﻟﺿﺑﻁ ﻋﺩﺩ ﺍﻧﺯﻉ ﺙ ﻣﻥ ﺍﻟﻣﺗﺣﺭﻙ ﺍﻟﺟﺯء ﻳﺳﺎﺭ ﻋﻠﻰ ﺿﺑﻁ ﻣﻔﺗﺎﺡ ﺃﻭ ﺭﺑﻁ ﻣﻔﺗﺎﺡ ﻭﺟﻭﺩ ﺷﺧﺻﻳﺔ ﺇﺻﺎﺑﺔ ﺣﺩﻭﺙ ﺇﻟﻰ ﻳﺅﺩﻱ ﺍﻟﻛﻬﺭﺑﺎﺋﻳﺔ ﺍﻟﻌﺩﺓ ﻭﺑﻳﻥ ﺑﻳﻧﻙ ﻣﻧﺎﺳﺑﺔ ﻣﺳﺎﻓﺔ ﺍﺗﺭﻙ ﺍﻟﻛﻬﺭﺑﺎﺋﻳﺔ ﺍﻟﻌﺩﺓ ﻣﻥ ﺗﻘﺗﺭﺏ ﻻ ﺝ ﺍﻷﻭﻗﺎﺕ ﺟﻣﻳﻊ ﻓﻲ ﺗﻭﺍﺯﻧﻙ ﻋﻠ...

Page 11: ... 949454 4 M5 32 937807 8 D5 25 33 949424 4 M5 34 949454 8 M5 35 999043 2 36 1 945161 2 36 2 961781 2 AUT 38 1 A B C D 39 1 958049 1 D8 2 39 2 940778 1 D8 2 40 937631 1 41 954017 2 D4 12 42 1 986201 1 42 2 931573 1 HOL AUT 42A 956632 1 AUS GBR FRG FRA ESP SUI 43 953261 1 44 1 956613 1 100V 127V 44 2 957556 1 220V 240V 44 3 990373 1 AUS 45 1 953243 1 45 2 1 NZL ITA 46A 994273 1 47A 981010 1 48 95914...

Page 12: ...Hitachi Koki Co Ltd 508 Code No C99216851 M Printed in Malaysia 000Book SAT 180 indb 12 000Book SAT 180 indb 12 2015 06 11 14 50 28 2015 06 11 14 50 28 ...

Reviews: