CHAPTER 5 OPERATION
10
5.2 Operate with Rotational speed command
〔
min
- 1
〕
Following information indicate the example of the inverter control data at P046: 21, P047: 71 and P049: 4.
See Chapter 6 about explanation of Polled I/O message.
Explanation on each data frame.
[Output frame]
(1) Stop command. Set rotational speed:1800min
-1
(0708hex). Acceleration / Deceleration command are
dependant on the inverter setting. Both rotational speed and run command set from DeviceNet.
(2) Forward running command.
(3) Change rotational speed command: 600min
-1
(0258hex).
(4) Stop command.
(5) Reverse running command. Set rotational speed:1800min
- 1
(0708hex).
(6) Stop command.
[Input frame]
(7) Stop condition
(8) While the inverter is forward run condition and accelerating, “XX” represents rotational speed.
(9) Constant speed condition. Revolutions arrive at 1800min
- 1
.
(10) Deceleration condition.
(11) Constant speed run condition. Revolutions arrive at 600min
- 1
.
(12) Deceleration condition.
(13) Stop condition.
(14) The inverter is in the reverse run condition and accelerating.
(15) Constant speed condition. Revolutions arrive at 1800min
- 1
.
(16) Deceleration condition.
(17) Stop condition.
(8)
(7)
(17)
(16)
(15)
(14)
(13)
(12)
(11)
(10)
(9)
1800
min
-1
60
00
08
07
62
00
08
07
60
00
58
02
61
00
58
02
70
03
00
00
78
05
xx
xx
F8
04
08
07
78
04
xx
xx
70
03
00
00
74
05
xx
xx
F4
04
58
02
74
05
xx
xx
F4
04
08
07
74
04
xx
xx
61
00
08
07
70
03
00
00
60
00
08
07
600
min
-1
1800
min
-1
IN
(6)
(5)
(4)
(3)
(2)
(1)
3Byte
0Byte
OUT
Reverse
running
Forward
running
3Byte
0Byte