“C” Group: Intelligent Terminal Functions
Configur
ing
Dr
iv
e P
a
ra
m
e
ters
3–42
NOTE:
Settings C_81 and C_82 are factory-calibrated for each inverter. Do not change
these settings unless absolutely necessary. Note that if you restore factory defaults for all
parameters, these settings will not change.
C_43 Arrival frequency
setting for deceleration
Sets the frequency arrival
setting threshold for the output
frequency during deceleration
✘
0.0
0.0
0.0
Hz
ARV DEC 000.0Hz
C_44 PID deviation level
setting
Sets the allowable PID loop
error magnitude (absolute
value), SP - PV, range is 0.0 to
100%, resolution is 0.1%
✘
3.0
3.0
3.0
%
OV PID 003.0%
C_81 O input span calibration Scale factor between the
external frequency command
on terminals L – O (voltage
input) and the frequency output
✘
Factory-calibrated
—
ADJ-O 082
C_82 OI input span calibra-
tion
Scale factor between the
external frequency command
on terminals L – OI (current
input) and the frequency output
✘
Factory-calibrated
—
ADJ-OI 066
C_91 Debug mode enable
(Reserved) DO NOT EDIT
✘
00
00
00
—
INIT DEBG OFF
C_92 Core monitor address
(Reserved) DO NOT EDIT
✘
0000
0000
0000
—
(not displayed)
C_93 Core monitor date
(Reserved) DO NOT EDIT
✘
—
—
—
—
(not displayed)
C_94 Core set address
(Reserved) DO NOT EDIT
✘
D_01
D_01
D_01
—
(not displayed)
C_95 Core set date
(Reserved) DO NOT EDIT
✘
00
00
00
—
(not displayed)
“C” Function
Run
Mode
Edit
Defaults
Func.
Code
Name /
SRW Display
Description
–FE
(CE)
–FU
(UL)
–FR
(Jpn)
Units