SJ200 Inverter
Appendix C
C–7
Fine Tuning Functions
“B” Group Parameters
Default Setting
User
Setting
Func.
Code
Name
-FE
F
(EU)
-FU
(USA)
B001
Selection of automatic restart
mode
00
00
B002
Allowable under-voltage power
failure time
1.0
1.0
B003
Retry wait time before motor
restart
1.0
1.0
B004
Instantaneous power failure /
under-voltage trip alarm enable
00
00
B005
Number of restarts on power
failure / under-voltage trip events
00
00
B012
Level of electronic thermal
setting
Rated
current for
each
inverter
Rated
current for
each
inverter
B212
Level of electronic thermal
setting, 2nd motor
Rated
current for
each
inverter
Rated
current for
each
inverter
B013
Electronic thermal characteristic
01
01
B213
Electronic thermal characteristic,
2nd motor
01
01
B021
Overload restriction operation
mode
01
01
B022
Overload restriction setting
Rated
current x
1.5
Rated
current x
1.5
B023
Deceleration rate at overload
restriction
1.0
30.0
B031
Software lock mode selection
01
01
B080
[AM] analog signal gain
100.
100.
B082
Start frequency adjustment
0.5
0.5
B083
Carrier frequency setting
5.0
5.0
B084
Initialization mode (parameters
or trip history)
00
00
B085
Country code for initialization
01
02
B086
Frequency scaling conversion
factor
1.0
1.0
Summary of Contents for SJ200 Series
Page 49: ...4 15 Remove the housing housing ...
Page 54: ...5 5 5 1 構造図 5 11 ...
Page 55: ...5 6 5 1 構造図 6 11 ...
Page 56: ...5 7 5 1 構造図 7 11 ...
Page 57: ...5 8 5 1 構造図 8 11 ...
Page 58: ...5 9 5 1 構造図 9 11 ...
Page 59: ...5 10 5 1 構造図 10 11 ...
Page 60: ...5 11 5 1 構造図 11 11 ...
Page 61: ...SJ200 002 004 005NFEF Slide type ...
Page 62: ...SJ200 007 011NFEF 004 007HFEF Slide type ...
Page 63: ...SJ200 015 022NFEF 015 040HFEF Slide type ...
Page 64: ...SJ200 055 075HFEF Slide type ...