Removing the housing cover
There are several ways which depend on the scale of the housing cover.
scale (small) : (200V class ) 0.2kW, 0.4kW, 0.75kW
scale (middle): (200V class ) 1.5kW, 2.2kW, 3.7kW
(400V class ) 0.4kW – 3.7kW
Scale (small)
1.Re mo ve t he m on it or c ove r, front c ove r a nd re a r c ove r.
W he n re mov in g t he mon it or c ove r, p le a se re m ove t he c o mm un ic a t ion c a b le
from t he front c ove r s ide .
2.Insert the minus screw driver between the cooling fin and the housing, and unlock the tabs
(4 points at the left and right side) .
3. Remove the housing.
ho us i n g
mo ni to r c o v e r
fr o n t c o v e r
r e a r c o v e r
ta b 1
ta b 2
ta b 3
ta b 4