ENGLISH
– 4 –
B-2. Operating Instruction for the DRY CONTACT for RAK-18/25/35PSA
OPEN
CLOSE
a
b
REMOVE
AIR CONDITIONER
Operating
AIR CONDITIONER
Standby
CLOSE
INSERT
OPEN
CARD
KEY
(DOOR
SWITCH)
contact
type
contact
type
[Notes]
Take care, to ensure the cut JP connector cannot come in contact with other
local components.
☆
For JP1, Dry contact function will be selected when it is "cut" in the Dry
contact function selection.
☆
For the selection of Contact a or Contact b, cut JP2 according to the Dry
contact setting.
Main PWB
Contact type a
Contact type b
JP1
JP2
Cut
Cut
Cut
Connected
Preparation for Dry contact function correspodence.
Dry Contact function is "Enable" by cutting JP1.
Select a proper setting for dry contact input logic
depending on the contact type as shown below.
Select Contact type a or Contact type b by cutting
JP2.
CN6
JP1
JP2
Jumper wire