background image

NOTE

• 

If during operation this        is indicated then function 

cannot be selected.

"         " will disappear from the screen of normal mode.

2 Select "Yes" by pressing "

" or "

" and press "OK".

When unit is OFF, select "Filter Sign Reset" from the menu 

and press "OK".

  The confirmation screen will be displayed.

When the unit is operated for a total of about 200 hours, 

"         " will be indicated on the screen of normal mode, it is 

time to clean the filter.

This function is used to turn off the filter sign indication.

( Except auto filter cleaning models )

5.8  FILTER SIGN RESET ("Functions" menu)

NOTE

• 

Indicated value shall be regarded as a guide only.

The heating power consumption will be displayed.

 

Press "

" or "

", the cooling power consumption will be 

displayed.

 

Press "

" or "

" repeatedly, the heating power 

consumption and the cooling power consumption will be 

displayed alternately.

The display in operation

The display in stop

Select "Info" from the menu and press "OK".

  The receiving screen will be displayed.

This is the function to display the monthly power consumption 

on the remote controller screen.

5.7  INFO FUNCTION ("Functions" menu)

- 18 -

Summary of Contents for SPX-WKT2

Page 1: ...Русский Suomi Nederlands Svenska Ελληνικα Português Español Italiano Deutsch Français English MODEL SPX WKT2 WIRED REMOTE CONTROLLER INSTRUCTION MANUAL ...

Page 2: ...ATION Functions menu 10 5 4 WEEKLY TIMER OPERATION Functions menu 11 5 5 LEAVE HOME OPERATION Functions menu 15 5 6 POWERFUL OPERATION Functions menu 17 5 7 INFO FUNCTION Functions menu 18 5 8 FILTER SIGN RESET Functions menu 18 5 9 CLEAN OPERATION Functions menu 19 5 10 OPERATION LOCK Functions menu 20 5 11 DAYLIGHT SAVING TIME Remocon Settings menu 21 6 ECO OPERATION 22 6 1 Eco operation 22 6 2 ...

Page 3: ...ck and fire Please contact your agent if you need to remove and reinstall the remote controller Electric shock or fire may occur if you remove and reinstall the remote controller yourself improperly Should abnormal situation arise like burning smell please stop operating the unit and turn off the circuit breaker Contact your agent Fault short circuit or fire may occur if you continue to operate the un...

Page 4: ...Indicator Fan Speed Indicator START STOP Button Operation indicator lamp Press this button to start operation Press it again to stop operation Operation Indicator Lamp Lit in normal operation and flashes during fault conditions Operation Guide Indicator Eco Mode and Forced Cooling setting and External device operation indicator Operation Mode Indicator Room Temperature Indicator Around Remote Contr...

Page 5: ...o the normal mode 5After the setting is completed press OK and the confirmation screen will be displayed 3Press or and select yy mm dd hh mm 4Press or to change the setting Press or keep or to adjust numbers 1Press menu Select Remocon Settings from the menu and press OK 2Select Adjusting Date Time from the menu and press OK This function is used to adjust the date and time Periodic time setting is ...

Page 6: ...range can be set between 16 C and 32 C Cooling Operation COOL To decrease the room temperature Temperature range can be set between 16 C and 32 C Fan Operation FAN To circulate the air in the room 3 MODE Function 2 By pressing or the operation mode will be changed as follows 1 Press or and select MODE 4 3 OPERATION MODE SELECT 2 Changing Setting When the item MODE SPEED SWING OR TEMP is selected p...

Page 7: ... swing right and left Press again The deflectors will stop in the current position 2 To start cancel auto swing operation NOTE For the indoor unit without the auto swing operation the indication of SWING will not be displayed on LCD The display for models of vertical swing only The display for models of vertical and horizontal swing 1 Press START STOP Make sure that the operation started Press or a...

Page 8: ... 2 2 When filter sign is turned on Page 2 2 Page 2 2 The display during operation Page 1 2 The display during stop Page 1 2 Select the Remocon Settings Select the Functions NOTE The Functions menu items vary depending on which is displayed in the stop and in operation 1 Press menu Select Functions or Remocon Settings by pressing or from the menu and press OK NOTE Unable to set If the function with ...

Page 9: ...ntents are switched in order of Not Used Once Everyday by pressing or When ON Time or OFF Time is selected the setting time can be set every 10 minutes by pressing or Press and hold or the setting time will change more quickly 2 Press or to select the setting items The setting items are displayed Timer Op ON Time and OFF Time NOTE If the present time has not been set yet automatically Adjusting Da...

Page 10: ... each setting content for the selected item When Timer Op is selected the setting contents are switched in order of Not Used Used by pressing or When Set time is selected the setting time can be set 1 hour 2 hours 3 hours and 7 hours by pressing or cyclically 2 Press or to select the setting items The setting items are displayed Timer Op and Set time NOTE If the present time has not been set yet a...

Page 11: ...numbers 4 Select the schedule No from 1 to 5 by pressing or Select ON Time OFF Time or Setting Temperature by pressing or Set the ON OFF timer and temperature by pressing or operation and stop will be displayed on LCD 3 Select the day of the week from Monday to Sunday by pressing or Press OK NOTE If the present time has not been set yet automatically Adjusting Date Time will be displayed In this c...

Page 12: ...Setting screen NOTE The schedule is not yet memorized at this section 3 Select the day of the week to paste by pressing or Press ECO the selected day of the week are displayed in or Press OK the copy based schedule is pasted in the selected day of the week The copy base day of the week is displayed in a double frame 2 Select the day of the week to copy by pressing or Press ECO Select the day of co...

Page 13: ...en will be displayed NOTE The deleted schedule is not yet memorized at this section 3 Select the schedule No 1 to 5 you want to delete by pressing or Press ECO The timer clear screen will be displayed Press OK the schedule will be deleted 2 Select the day of the schedule you want to delete by pressing or Press OK Timer Setting screen will be displayed How to delete Weekly schedule setting 1 Select...

Page 14: ...FF is set in this function This function is used to apply for long period of holidays 5 4 4 Schedule ON OFF setting NOTE will be turned off when the holiday setting is activated 4 Select Yes by pressing or and press OK The holiday setting will be confirmed and the screen will return to the normal mode 3 Press OK after the setting is completed The confirmation screen will be displayed and will be chan...

Page 15: ...enu and press OK The screen of Set Period selection will be displayed 5 5 2 Day timer operation 4 Set the temperature by pressing or Temperature range can be set between 10 C and 16 C Keep pressing and the value will change more quickly 3 Select Yes by pressing or and press OK The leave home operation will be started and the screen will return to the normal mode Leave home operation display 2 Sele...

Page 16: ...oor temperature After reaching the set number of operation days for leave home or leave home operation is canceled the unit will operate in previous mode Powerful and Eco operations are not applicable during leave home operation For multi connection NOTE During leave home operation fan speed and air deflector s position cannot be changed When leave home operation is started implementation of Simple...

Page 17: ...enu and press OK The confirmation screen will be displayed Select Yes by pressing or and press OK Or Press START STOP Or 5 6 2 To cancel Powerful operation Powerful operation ends in 20 minutes Then the system automatically operates with the previous settings used before powerful operation will be indicated in fan speed area 2 Select Yes by pressing or and press OK The setting will be confirmed and ...

Page 18: ...turn off the filter sign indication Except auto filter cleaning models 5 8 FILTER SIGN RESET Functions menu NOTE Indicated value shall be regarded as a guide only 2 The heating power consumption will be displayed Press or the cooling power consumption will be displayed Press or repeatedly the heating power consumption and the cooling power consumption will be displayed alternately The display in oper...

Page 19: ...played the normal mode Select Clean from the menu and press OK The confirmation screen will be displayed Select Yes by pressing or and press OK Press START STOP Or 5 9 2 To cancel Clean operation Total time taken for Clean operation is 60 minutes During this operation Heating or Fan operation shall operate During this operation the operation lamp of indoor unit is blinking 2 Select Yes by pressing ...

Page 20: ...l be set and will be indicated on the screen of normal mode 3 Select Yes by pressing or and press OK When Heating mode lock is selected When Cooling mode lock is selected When this function is not used 2 By repeatedly pressing or the indication is changed in order of No Setting COOL HEAT Select the function target and press OK The confirmation screen will be displayed When filter sign is turned on T...

Page 21: ...op Daylight Saving Time 3 The confirmation screen will be displayed Select Yes by pressing or and press OK to confirm the setting The screen will return to the normal mode 2 The Daylight Saving Time screen displays Select Set 1h forward by pressing or and press OK 1 Select Daylight Saving Time from the menu and press OK 5 11 1 To start Daylight Saving Time This function adjusts time forward or backw...

Page 22: ...tomatically starts energy saving operation by shifting the set temperature in two steps 6 2 Eco operation with sensor NOTE Eco operation will not be effective when power consumption is low When Powerful operation is set Eco operation is canceled After auto restart Eco operation is canceled and previous operation mode shall start For multi model connections energy saving operation shall start only b...

Page 23: ...the explanation of each icon on LCD is required NOTE If the menu screen remains unchanged for approximately 10 minutes the screen will automatically return to the normal mode 3 To return to the normal mode press return help 2 Select the item from the help menu by pressing or and press OK 1 Press return help The help menu will be displayed The explanation of indicators on LCD and operations can be ...

Page 24: ...help The screen will return to the help menu To return to the normal mode press return help again 4 Press return help The screen will return to the operation item 3 Press or to scroll the text up and down 2 Select the operation from the list by pressing or and press OK The explanation of the selected operation will be displayed 1 Select About Operation from the help menu and press OK The explanati...

Page 25: ...te with this remote controller and the indoor unit The operation indicator Red is flashing and it continues to display the Connecting on the LCD 8 2 1 Communication failure 8 2 In abnormal condition Turn on ECO Auto Off Mode will be indicated on the screen of normal mode when the operation is stopped by Eco Auto Off function Turn on It is the setting performed by service personnel or sales agent If E...

Page 26: ......