ASSEMBLY INSTRUCTIONS 

• 

Attach the display module CFL connector to the output connector on the CFL inverter.  

• 

Attach the inverter input cable to the input connector on the CFL inverter. 

• 

Connect the flying leads of the inverter input cable to power according to the CFL inverter specification. 

• 

Insert the flexible printed circuit adapter cable into the top contact ZIF connector on the LCD module.  
Note: this connector has a retaining bar which must be pulled gently to release, insert cable and push 
retaining bar back into place.  

• 

Connect the correct signals to the through holes of the flexible printed circuit adapter cable according to 
the display specification and pin assignment. 

 

IMPORTANT NOTES  

1.  USE CORRECT POWER-UP SEQUENCE OF DATA 

2.   DO NOT APPLY POWER TO INVERTER BOARD WITHOUT CFL CONNECTED. THIS WILL RESULT 

IN INVERTER FUSE FAILURE 

3.   WHEN POWERED-UP THE INVERTER BOARD GENERATES HIGH VOLTAGES USE CAUTION 

WHEN ON. 

 