lcd technical information
Last Update: 02/02/04
Page: 2/2
File: STARTSP14N001
ASSEMBLY INSTRUCTIONS
•
Attach the display module CFL connector to the output connector on the CFL inverter.
•
Attach the inverter input cable to the input connector on the CFL inverter.
•
Connect the flying leads of the inverter input cable to power according to the CFL inverter specification.
•
Insert the flexible printed circuit adapter cable into the top contact ZIF connector on the LCD module.
Note: this connector has a retaining bar which must be pulled gently to release, insert cable and push
retaining bar back into place.
•
Connect the correct signals to the through holes of the flexible printed circuit adapter cable according to
the display specification and pin assignment.
IMPORTANT NOTES
1. USE CORRECT POWER-UP SEQUENCE OF DATA
2. DO NOT APPLY POWER TO INVERTER BOARD WITHOUT CFL CONNECTED. THIS WILL RESULT
IN INVERTER FUSE FAILURE
3. WHEN POWERED-UP THE INVERTER BOARD GENERATES HIGH VOLTAGES USE CAUTION
WHEN ON.