--- 8 ---
Fig. 3
8-4. Wiring Diagram
Internal Wire (Blue)
[24]
Tab Terminal (Brown)
[23]
8-5. Insulation Tests
On completion of disassembly and repair, measure the insulation resistance and conduct the dielectric strength
test.
Insulation resistance: 7 M
Ω
or more with DC 500 V megohm tester
Dielectric strength:
AC 4,000 V/1 minute, with no abnormalities
• • • • • • •
220 V --- 240 V
AC 2,500 V/1 minute, with no abnormalities
• • • • • • •
110 V --- 127 V
8-6. No-load Current Value
After no-load operation for 30 minutes, the no-load current value should be as follows:
Internal Wire (Brown)
[5]
Slide Switch
[20]
Black or brown
Cord
White or blue
Tab Terminal (Blue)
[6]
Noise Suppressor
[4]
For NZL, AUS, EUROPE, CHN
Pillar Terminal
[19]
Voltage (V)
Current (A) max.
1.50
110 V
1.45
120 V
220 V
0.75
230 V
240 V
Stator
[22]
Stator
[22]