OEM MANUAL:K6602924
5 COMMAND DESCRIPTIONS
Revision: 1 / Date: 2003.03.06
Page: 198 / 273
If the last valid APTPL bit value received by the controller is zero, the loss of power
in the target shall release the persistent reservation for all logical units and remove
all reservation keys. If the last valid APTPL bit value received by the controller is one,
the logical unit shall retain any persistent reservation(s) that may be present and all
reservation keys for all initiators even if power is lost and later returned.
Table 5.89 summarizes which fields are set by the application client and interpreted
by the device server for each service action and scope value. The APTPL bit in the
PERSISTENT RESERVE OUT parameter list, specified in the previous paragraph,
is not summarized in Table 5.89.
Table 5.89
PERSISTENT RESERVE OUT Service Actions and Valid Parameters
Parameters
Service
Action
Allowed scope
type
Reservation
key
Service
action
reservation
key
Scope-specific
address
REGISTER
Ignored
Ignored Valid
Valid
Ignored
REGISTER
AND
IGNORE
EXISTING
KEY
Ignored
Ignored Ignored
Valid
Ignored
RESERVE
LU_SCOPE
Ignored
ELEMENT_SCOPE
Valid
Valid
Ignored
Valid(element)
RELEASE
LU_SCOPE
Ignored
ELEMENT_SCOPE
Valid
Valid
Ignored
Valid(element)
CLEAR
Ignored
Ignored Valid
Ignored
Ignored
LU_SCOPE
Ignored
PREEMPT
ELEMENT_SCOPE
Valid
Valid
Valid
Valid(element)
LU_SCOPE
Ignored
PREEMPT
AND ABORT ELEMENT_SCOPE
Valid
valid
Valid
Valid(element)
PERSISTENT RESERVE OUT:(5Fh)