OEM MANUAL:K6602924
5 COMMAND DESCRIPTIONS
Revision: 1 / Date: 2003.03.06
Page: 98 / 273
The Parameter Length field specifies the length in bytes of the following
Parameter Value field. If the initiator sends a parameter length value that
results in the truncation of the parameter value, the drive will terminate the
command with CHECK CONDITION status. The sense key will be set to
ILLEGAL REQUEST with the additional sense code set to INVALID FIELD IN
PARAMETER LIST.
If the initiator sends a log parameter value that is not supported by the drive, the
drive will terminate the command with CHECK CONDITION status with a sense
key of ILLEGAL REQUEST and an additional sense code of INVALID FIELD IN
PARAMETER LIST.
Supported Log Pages (Page Code = 00
H
)
The supported log page is only defined for LOG SENSE command.
It returns the list of log pages implemented by the drive.
Table 5.23 Supported Log Pages
Bit
Byte
7
6
5
4
3
2
1
0
0
Reserved
Page Code(00
H
)
0
0
0
0
0
0
0
0
1
Reserved
0
0
0
0
0
0
0
0
2
(MSB)
Page Length (000A
H
)
3
(LSB)
4
00
H
(Supported Log Page)
5
02
H
(Error Counter Write Page)
6
03
H
(Error Counter Read Page)
7
05
H
(Error Counter Verify Page)
8
06
H
(Non-Medium Error Page)
9
07
H
(Last n Error Events Page)
10
0D
H
(Temperature Page)
(cont’d)
LOG SELECT:(4Ch)