Chapter 12. When Warning or Fault Occurs
12-8
(2) Faults that do not stop the ink jet
Fault message list (faults that do not stop the ink jet)
Message
No.
Message
Message description
Solution
E-028
Print Data
Changeover Error M
The print data change procedure was
incomplete.
●
Check the data entered
E-040
External
Communication
Error nnn
The serial communication port had a
data error.
●
Note the error code and see that no
more errors occur.
(Refer to Communication manual)
E-042
Ink Drop Charge
Too High
The detection level of ink drop charge is
too high.
●
Clean the gutter, deflection
electrode, and its surroundings.
●
Check the ink pressure.
(
*1
Technical Manual 5.9)
●
Adjust the excitation V-ref. value so
that ink drops are produced better.
(
Technical Manual 5.10)
●
Make sure that the ink stream has
been correctly recovered.
E-043
Barcode Short On
Numbers
The number of characters for the selected
barcode type is insufficient.
●
Configure the number of barcode to
appropriate value.
●
(
Technical Manual 8.1)
E-044 Shutdown Fault
The shutdown process failed.
●
Turn the printer power OFF by main
switch.
E-045 Count Overflow
The calculation result of the count
multiplier overflowed.
●
Change the count multiplier setting.
E-049 Print Overlap Fault
The next print target detection signal
turned ON before printing was
completed.
●
Decrease the spacing.
●
If the print target detection signal is
chattering, use the sensor filter
setting. (
5.8.1.)
E-050
Print Head Cover
Open
The print head cover is open.
●
Install the print head cover
E-052
Target Sensor Timer
Out
The print target detector blocking time is
greater than the [Target Sensor Timer]
value.
●
If the print target is stopped with it
blocking the print target detector,
remove the target.
●
Change the [Target Sensor Timer]
setting value. (
5.8.1.)
E-053
Target Spacing Too
Close
The print target detection signal turned
ON five or more times before printing
was started during non-repeat printing.
●
Move the print target detector closer
to the print head.
E-054
Print Data
Changeover In
Progress S
The unit became [print.-in-progress]
during print data changeover.
●
Change the [Print data changeover
error] setting to [Disable] in [User
environment setup]. (
9.1.).
●
Change the print data changeover
timing or print start timing.
E-056 Blank Print Items
Some print description items are not set.
●
Change the print description setting.
(Continue to next page)
*1
: Indicates the reference section.
Summary of Contents for UX2 Series
Page 6: ......
Page 14: ......
Page 17: ...iii ...
Page 24: ......
Page 37: ...2 1 Chapter 2 2 Specifications Chapter 1 Chapter 2 Chapter 3 Chapter 4 Chapter 5 ...
Page 41: ......
Page 42: ...This page is blank ...
Page 53: ......
Page 54: ...This page is blank ...
Page 82: ......
Page 118: ......
Page 156: ...This page is blank ...
Page 205: ...Chapter 7 Auxiliary Functions 7 49 Chapter 7 HOME screen after editing widget ...
Page 206: ...This page is blank ...
Page 228: ...This page is blank ...
Page 247: ......
Page 248: ...This page is blank ...
Page 258: ...This page is blank ...
Page 276: ...This page is blank ...
Page 292: ......
Page 293: ...13 1 Chapter 13 13 Troubleshooting Guide Chapter 13 Chapter 11 Chapter 12 Chapter 14 Appendix ...
Page 296: ...This page is blank ...
Page 297: ...14 1 Chapter 14 14 Emergency Procedures Chapter 14 Chapter 11 Chapter 13 Chapter 12 Appendix ...
Page 299: ......
Page 300: ......