Storing the storage system
If the storage system does not receive power for more than six months, the
battery can become discharged and possibly damaged. To avoid this
situation, charge the battery for more than three hours at least once every
six months.
Note:
Do not store the equipment in an environment with temperatures of
104ºF (40ºC) or higher because battery life will be shortened.
Using flash module drives
Observe the following guidelines when handling the listed flash module drives
(FMDs). The types of FMDs are equipped with a battery or capacitor.
Power up the flash module drives using power from the storage system for at
least 90 minutes every month. Failing to do so may render a flash module
drive unusable and will abrogate replacement under the terms of the
warranty.
Model Name
Drive type
Battery
Capacitor
DKC-F710I-1R6FM
NFH1A-P1R6SS
yes
N/A
NFH1C-P1R6SS
yes
N/A
NFH1D-P1R6SS
N/A
Yes
DKC-F710I-3R2FM
NFH1B-P3R2SS
yes
N/A
NFH1C-P3R2SS
yes
N/A
NFH1D-P3R2SS
N/A
yes
DKC-F810I-1R6FN
NFHAE-Q1R6SS
N/A
yes
NFH1D-P1R6SS
N/A
yes
DKC-F810I-3R2FN
NFHAE-Q3R2SS
N/A
yes
NFH1D-P3R2SS
N/A
yes
DKC-F810I-6R4FN
NFHAE-Q6R4SS
N/A
yes
NFH1D-P6R4SS
N/A
yes
Guidelines for handling the FMDs
Follow the guidelines to avoid damaging the components when handling
FMDs.
• Check the main edge connector of the drive for any damage, deformation,
dust or debris before installing.
80
Maintaining the storage system
Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide
Summary of Contents for Virtual Storage Platform G400
Page 1: ...Hitachi Virtual Storage Platform G600 Hardware Reference Guide MK 94HM8022 05 June 2016 G400 ...
Page 6: ...6 Hitachi Virtual Storage Platform G400 G600 Hardware Reference Guide ...
Page 16: ...16 Preface Hitachi Virtual Storage Platform G400 G600 Hardware Reference Guide ...
Page 123: ...Hitachi Virtual Storage Platform G400 G600 Hardware Reference Guide ...