3 - 4
2.6.2 How to Start the MAP
(1)
Turn the personal computer on and start the MS-
DOS system.
Note:
Refer to the instruction manual of the personal
computer for how to start computer.
(2)
Load the adjustment floppy disk in to disk drive A
and press
A:
[ENTER]. (Display 2-1)
(3)
Press
MAP_IBM
[SPACE]
1
[ENTER]. (Display 2-2)
Note:
When you use a personal computer with two serial
interface connectors and connect the DSP jig to
serial interface connector 2, press MAP_IBM 2.
(4)
Select the number accodding to the model.
(Display 2-3)
If [ESC] (escape) is pressed, the display before the
MAP starts (MS-DOS) is restored.
Notes:
1. If the required model is not found, press the
P
key and select the model from the next screen.
2. If you select number without a model name by
mistake, the message shown in "MESSAGE
WHEN OPERATED BY MISTAKE" will appear
in the computer's display (Display 2-4).
Press any key to return the display to MODEL
SELECT dispaly.
(5)
Press
Y
key. (Display 2-5)
If
N
key is pressed, the computer's display returns to
MODEL SELECT display.
(6)
Refer to display 2-6.
2.6.3 Initial Setting by Model
Before Starting Initial Setting
1. This item describes how to initialize the EEPROM.
Be sure to perform this item after replacing EEPROM
or the VCA circuit board.
When other components are replaced, normally, it
is not necessary to initialize the EEPROM.
2. Be sure to perform the following adjustments after
completing the initial setting.
2.6.4
Digital Adjustment Procedure
2.6.5
Autofocus Adjustment Procedure
2.6.6
Stabilizer Adjustment Procedure
[Except for VM-E578LE(AU)/E578LE(SW)]
2.6.7
Spot Noise Adjustment Procedure
2.7
Color LCD Monitor Adjustment
3.5
System Control/Servo Circuits Adjustment
(1)
Start the MAP.
(2)
Refer to display 2-6.
(3)
Press
A
key.
(4)
Refer to display 3-1.
(5)
Press
Y
key to start.
Note
:Press
N
to return to MAIN MENU display.
(6)
Perform adjustment according to the computer
display hereafter.
See "4. Error Messages" if an error message
appears on the computer display.
Display & Figs
Display 2-1
C>A:
A>
C>A:
A>MAP_IBM 1
Display 2-2
***********************************************************
MODEL SELECT
***********************************************************
[1]
××××××××
[2]
××××××××
[3]
××××××××
[4]
××××××××
[5]
××××××××
[P]
NEXT SELECTION
[ESC] END
Please select the type of the set
Press [1] - [5] or [P] or [ESC]
Display 2-3
CAN NOT FIND THE DATA FILE
**** PRESS ANY KEY ****
Display 2-4
MESSAGE WHEN OPERATED BY
MISTAKE
Selected model is ××××××××
Are you sure ? (Y/N)
Display 2-5
Display 2-6
MAIN MENU
***********************************************************
MANUAL ADJUSTMENT PROGRAM
***********************************************************
[A]
DATA INITIALIZE
[B]
ADJUSTMENT
[C]
VCR ADJUSTMENT
[D]
AUTO FOCUS
[E]
STABILIZER
[F]
SPOT NOISE
[G]
LCD
[ESC] END
Please select [A] - [G] or [ESC]
Display 3-1
<< DATA WRITING >>
START TO SEND DATA. (Y/N)