SSB2
CCI command
Cause of error
FF6D
paircreate
The command ended abnormally because the specified P-VOL is
used by a cascaded pair.
FF72
paircreate, pairsplit,
pairresync,
pairresync -restore
The Thin Image pair task failed because a snapshot tree is being
deleted.
FF7A
paircreate
The Thin Image pair could not be created because the V-VOL
capacity exceeded the amount reserved for the pool.
FF7C
paircreate
The Thin Image pair whose snapshot data is stored in the DP pool
could not be created because system option mode 1120 is set to
ON.
This table lists the SSB2 codes when SSB1 is B980, the related CCI
command, and the cause of the error.
SSB2
CCI command
Cause of error
B901
paircreate,
pairresync, pairsplit,
pairsplit -S
The specified port is for NAS Platform (system LU).
B903
paircreate,
pairresync
The selected resource belongs to NAS_Platform_System_RSG.
Notes on using Thin Image primary volumes as TrueCopy,
ShadowImage, or Universal Replicator pair volumes
The
raidcom modify snapshot -snapshot_data create
or
raidcom modify
snapshot -snapshot_data clone
CCI command might return the error code
EX_EWSTOT
(timeout) and terminate abnormally when the status of a pair in a
Thin Image consistency group cannot be changed.
Following are possible reasons why the pair status cannot be changed:
• The Thin Image primary volume is used as a Universal Replicator S-VOL,
and you are reaching the UR journal volume capacity limit.
• The Thin Image license is invalid.
• The Thin Image pair volumes are blocked.
• The current status of the Thin Image pair does not allow the
raidcom
modify snapshot -snapshot_data create
or
raidcom modify snapshot
-snapshot_data clone
command to run on the pair.
• The current status of the Thin Image, ShadowImage, TrueCopy, or
Universal Replicator pair does not allow the
raidcom modify snapshot -
snapshot_data create
or
raidcom modify snapshot -snapshot_data
clone
command to run on the pair.
After resolving these error conditions, make sure that all pairs in the
consistency group are in "PAIR" status before running the
raidcom modify
222
CCI command reference for Thin Image
Hitachi Thin Image User Guide for Hitachi Virtual Storage Platform G Series and F Series