MAINTENANCE
7-81
10
Check Air Conditioner --- daily
1. Check pipe connections for refrigerant gas leakage.
If oil seepage is found around pipe connections, it indi-
cates possible gas leakage.
2. Check the condenser.
If the condenser fins become clogged with dirt or insects,
the cooling effect will be decreased. Be sure to keep it
clean at all times. (Refer to “Clean Radiator Core” in Main-
tenance Section.)
3. Check the compressor
After operating the air conditioner for 5 to 10 minutes,
touch the high-pressure side and low-pressure side pipes
with your hand. If normal, the high-pressure side pipe will
be hot, and the low-pressure side cold.
4. Check mounting bolts for looseness.
Confirm that the compressor mounting bolts and other
mounting/fastening bolts are securely tightened.
5. Inspect belt, check and adjust tension.
Visually check the compressor and fan belts for wear.
Check and adjust belt tension, referring to the illustration
(right).
If cool air does not come out, or any other abnormalities are
found in air conditioner system, see your authorized dealer
for inspection.
M1U1-07-086
Fan Pulley
Crank Pulley
Compressor Pulley
Tension Pulley
8 to 12 mm (0.32 to 0.47 in)
98 N (10 kgf, 22 lbf)
M1GR-07-007
Fan Pulley
Crank Pulley
Compressor Pulley
Alternator Pulley
5 to 6 mm (0.2 to 0.24 in)
98 N (10 kgf, 22 lbf)
150 mm
ZX200-3, 270-3 , 330-3 Class
ZX120-3, 180-3 Class
Summary of Contents for ZAXIS 120-3 class
Page 1: ......
Page 3: ......
Page 5: ......
Page 49: ...SAFETY SIGNS Europe Asia Middle and Near East Model Only S 38 MEMO ...
Page 131: ...BREAK IN 2 MEMO ...
Page 191: ...TRANSPORTING 6 MEMO ...
Page 290: ...HYDRAULIC CIRCUIT AND ELECTRICAL CIRCUIT 8 HYDRAULIC CIRCUIT M1V1 08 001 ...
Page 292: ...8 ELECTRICAL DIAGRAM ...
Page 293: ...HYDRAULIC CIRCUIT AND ELECTRICAL CIRCUIT 8 MEMO ...
Page 295: ...MAINTENANCE UNDER SPECIAL ENVIRONMENTAL CONDITIONS 9 MEMO ...
Page 351: ...SPECIFICATIONS 12 42 MEMO ...
Page 455: ...OPTIONAL ATTACHMENTS AND DEVICES 13 104 MEMO ...
Page 461: ...INDEX 14 MEMO ...