OPTIONAL ATTACHMENTS AND DEVICES
13-88
METRIC MEASURE
ZX280LC-3 Mono block boom, Arm 2.42 m, G 600 mm
Unit; kg
B: Load
point
height
m
A: Load radius
Max.
1.5 m
3.0 m
4.5 m
6.0 m
7.5 m
9.0 m
REACH
m
6.0
6740 * 5440
7.46
4.5
9590 * 9590 *
6870 * 4670
8.11
3.0
12340 * 10580
8950 * 7060
6860
4290
8.44
1.5
10050 * 6730
8050
4950
6700
4160
8.49
0
14720 * 9810
10690 * 6530
7920
4840
6900
4250
8.27
-1.5
10360 * 10360 * 14390 * 9830
10750 * 6480
7900
4820
7560
4640
7.75
-3.0
18020 * 18020 * 13290 * 9980
10040 * 6580
8470 * 5530
6.86
-4.5
14540 * 14540 * 10790 * 10340
8710 * 7920
5.42
ZX280LC-3 Mono block boom, Arm 3.11 m, G 600 mm
Unit; kg
B: Load
point
height
m
A: Load radius
Max.
1.5 m
3.0 m
4.5 m
6.0 m
7.5 m
9.0 m
REACH
m
6.0
5960 * 5960 * 5910 * 5520
4730 * 4730
8.19
4.5
8240 * 8240 * 6940 * 6940 * 6330 * 5370
4730 * 4140
8.78
3.0
11000 * 10940
8240 * 7180
6990 * 5170
5560 * 3900
4890 * 3830
9.09
1.5
13310 * 10180
9500 * 6800
7690 * 4970
6130
3800
5220 * 3720
9.14
0
14450 * 9820
10380 * 6540
7900
4810
5800 * 3780
8.93
-1.5
6820 * 6820 * 10250 * 10250 * 14590 * 9730
10730 * 6420
7820
4740
6610
4060
8.45
-3.0
11900 * 11900 * 16480 * 16480 * 13930 * 9820
10410 * 6450
7870
4790
7670
4680
7.65
-4.5
16970 * 16970 * 12190 * 10070
8980 * 6640
8170 * 6120
6.39
NOTE: When the lifting hook is used, the maximum allowable lifting load is 10 tons.
LIFTING CAPACITIES
NOTE: • Lifting capacity of the ZX series does not exceed 75%
of tipping load with the machine on firm, level ground
or 87 % of full hydraulic capacity. (ISO 10567)
• * Indicates load limited by hydraulic capacity.
A: Load radius
B: Load point height
C: Lifting capacity
A
C
B
M1G6-13-013
Summary of Contents for ZAXIS 120-3 class
Page 1: ......
Page 3: ......
Page 5: ......
Page 49: ...SAFETY SIGNS Europe Asia Middle and Near East Model Only S 38 MEMO ...
Page 131: ...BREAK IN 2 MEMO ...
Page 191: ...TRANSPORTING 6 MEMO ...
Page 290: ...HYDRAULIC CIRCUIT AND ELECTRICAL CIRCUIT 8 HYDRAULIC CIRCUIT M1V1 08 001 ...
Page 292: ...8 ELECTRICAL DIAGRAM ...
Page 293: ...HYDRAULIC CIRCUIT AND ELECTRICAL CIRCUIT 8 MEMO ...
Page 295: ...MAINTENANCE UNDER SPECIAL ENVIRONMENTAL CONDITIONS 9 MEMO ...
Page 351: ...SPECIFICATIONS 12 42 MEMO ...
Page 455: ...OPTIONAL ATTACHMENTS AND DEVICES 13 104 MEMO ...
Page 461: ...INDEX 14 MEMO ...