MAINTENANCE
7-37
Changing intervals for the standard filter paper
Breaker Operation
Availability
0 %
10 %
20 %
30 %
40 %
50 %
60 %
70 %
80 %
90 %
100 %
Full-Flow Filter
500
180
115
95
85
75
70
65
60
55
50
Hydraulic oil: 1000 hours
life time
1000
720
580
500
450
410
380
360
340
330
320
Hydraulic oil: 2000 hours
life time
2000
1310
980
780
650
550
480
430
385
350
320
Av
er
age
Br
eaker
Oper
ation
A
vailabilit
y
(%)
Changing Intervals (hour)
When using filter-paper element
0
200
400
600
800
1000
1200
1400
1600
1800
2000
0
10
20
30
40
50
60
70
80
90
100
Element Replacement Intervals
Changing Interval when using 1000-hour life time Hydraulic Oil