MAINTENANCE
7-41
ZX17U-5A
5. Remove oil using a suction pump. The hydraulic oil tank
capacity up to specified oil level is approximately A.
Model
A
ZX17U-5A
26 L (6.9 US gal)
6. Slowly loosen drain plug (3). Allow oil to drain.
7. After draining oil, remove suction filter (6) with cover (2).
IMPORTANT: When changing hydraulic oil, take care not
to enter foreign matters such as dust, water, or sand
into the hydraulic oil tank.
8. Clean the hydraulic oil tank interior and suction filter (6).
9. Install suction filter (6) and cover (2) to the hydraulic oil
tank.
10. Clean, install and tighten drain plug (3).
11. Add oil until it is between the marks on the oil level
gauge.
12. Bleed air from the hydraulic system.
(Refer to the "Bleed Air from Hydraulic System".
Wrench size:
13 mm
Tightening Torque:
20 N·m (2 kgf·m, 15 lbf·ft)
13. Replace suction filter (6) at the regular interval to keep
hydraulic oil clean and to extend the service life of the
hydraulic components.
3
MABA-07-020
MABA-07-025
2
6
Summary of Contents for Zaxis 17U-5A
Page 4: ......
Page 8: ...CONTENTS MEMO ...
Page 12: ...MACHINE NUMBERS 4 MEMO ...
Page 84: ...OPERATOR S STATION 1 18 MEMO ...
Page 86: ...BREAK IN 2 2 MEMO ...
Page 108: ...DRIVING THE MACHINE 4 14 MEMO ...
Page 228: ...MAINTENANCE 7 88 MEMO ...
Page 230: ...MAINTENANCE UNDER SPECIAL ENVIRONMENTAL CONDITIONS 9 2 MEMO ...
Page 232: ...STORAGE 10 2 MEMO ...
Page 240: ...TROUBLESHOOTING 11 8 MEMO ...
Page 250: ...SPECIFICATIONS 12 10 MEMO ...
Page 270: ...13 20 NUMERIC KEYPAD LOCK OPTIONAL ATTACHMENT MEMO ...
Page 274: ...INDEX 14 4 MEMO ...
Page 276: ......
Page 277: ......
Page 278: ......