MAINTENANCE
7-93
Check Air Conditioner Condenser
--- every 250 hours or 3 months
If condenser (1) is covered with dirt and/or insects, air
conditioner cooling performance will be reduced.
Remove dirt or stain from fins of condenser (1) using tap water.
In case the condenser has been severely contaminated, use a
soft brush. Do not use a hard brush, which may damage the
fins.
Check Air Conditioner Fan Belt
--- every 250 hours or 3 months
Check the belt for abnormal deflection and damage.
Check fan belt tension by depressing the midpoint shown with
mark in the illustration with the thumb. Deflection must be
as follows with a depression force of approximately 64 N (6.5
kgf, 14.4 lbf).
Deflection : approx. 7 mm (0.3 in)
Belt Tension Adjustment Procedure
1. Loosen lock nut (2) of tension pulley (4).
2. Move tension pulley (4) to adjust belt tension by turning
belt tension adjustment bolt (3).
3. Securely tighten nut (2).