MAINTENANCE
7-119
Clean Filler Port Strainer
Strainer (1) is provided on the filler port of the DEF/AdBlue®
tank. Clean strainer (1) if dirt or dust is observed.
d
CAUTION: Wear safety equipment such as safety
glasses or goggles, rubber gloves appropriate to
the job. Wash DEF/AdBlue® with clean water when it
contacts with the skin. If DEF/AdBlue® is accidentally
splashed into eyes, flush with water for 15 minutes or
longer and get emergency medical attention.
IMPORTANT: Take care not to allow dust to contaminate
the area when carrying out the work.
1. Remove strainer (1) from the filler port of the DEF/
AdBlue® tank.
2. Clean strainer (1) with compressed air pressure (lower
than 0.2 MPa (2 kgf/cm
2
, 30 psi)) or tap water.
3. Install strainer (1) on the filler port of the DEF/AdBlue®
tank.