7-62
MAINTENANCE
Interval
(hours)
Check Points
Abnormalities
Remedies
Daily Check
Contact surfaces of
flange joints
Leak (11)
Replace
Bolts
Loose or leak (11)
Retighten or replace
O-ring
Welded surfaces on
flange joints
Leak (12)
Replace
Every 250
hours
Flange joint neck
Crack (13)
Replace
Welded surfaces on
flange joints
Crack (12)
Replace
Clamps
Missing or deformation
Loose bolts
Replace or retighten
M4GB-07-059
M4GB-07-060
12
13
12
Fig.2
13
11