MAINTENANCE
7-89
Precautions for Using CC2602 Test Kit
Maintain coolant temperature to 10 to 54 °C (50 to 129.2
°F) while checking. Otherwise, incorrect color change may
result.
Compare the reagent color with the color specimen to
measure the concentration in daylight. In case it is difficult
to specify the color concentration through the comparison
of the reagent color with the color specimen, adopt the
lighter side concentration as a safer value.
The reagents provided in the test kit are sensitive to light,
heat, and excessive moisture so that they should be stored
in a plastic container. Unless the test papers are used, be
sure to close the container cover correctly.
Avoid to expose the test kit to the direct ray of the sun
while storing and maintain the ambient temperature of the
storing place to 32 °C (89.6 °F) or lower.
Concentration Check Table
% GLYCOL/FREEZEPOINT (°F)
DCA Unit/3.78L (1 US gal)
(DCA UNITS PER GALLON)
(SODIUM
MOLYBDATE
LEVEL)
(SODIUM NITRITE LEVEL)
The effective life time of the reagent is printed on the
upper section of the CC2602 container.
Do not use any reagents after the effective life time
expires.
If the reagent color has changed to light brown or
pink, avoid using such reagent.
If the color specimen was spoiled, wipe stain with a
cloth. Do not use any soap or solvent.
The reagent color continues to change from soon
after being dipped into coolant and stops after
it is dried up. Therefore, measure the coolant
concentration within the specified time range.
Summary of Contents for ZW 310-6
Page 4: ......
Page 10: ...CONTENTS MEMO ...
Page 14: ...INTENDED USE 2 MEMO ...
Page 57: ...SAFETY SIGNS S 43 ZW310 6 SS 3777 2 ...
Page 59: ...SAFETY SIGNS S 45 ZW330 6 92Z7B S 40EU ...
Page 246: ...BREAK IN 2 2 MEMO ...
Page 280: ...DRIVING MACHINE 4 20 MEMO ...
Page 460: ...MAINTENANCE 7 146 MEMO ...
Page 464: ...MAINTENANCE UNDER SPECIAL ENVIRONMENTAL CONDITIONS 9 4 MEMO ...
Page 468: ...STORAGE 10 4 MEMO ...
Page 474: ...TROUBLESHOOTING 11 6 MEMO ...
Page 498: ...INDEX 14 6 MEMO ...
Page 502: ...CONFORMITY MEMO ...
Page 506: ......