7-33
MAINTENANCE
Clean Torque Converter Air Breather
--- every 1000 hours
1. Open the machine right side cover. The air breather is
located near the accumulator.
2. Clean the vicinity around air breather (1).
Put a cover on the air breather port to prevent foreign
matter from entering.
d
WARNING: Be sure to wear safety glasses when
cleaning the air breather with compressed air.
3. Clean the air breather using compressed air.
If completely contaminated, wash the air breather with
a cleaning solvent, blow it dry and reinstall it.
4. Take care not to allow foreign matter to enter when
reinstalling the air breather.
95Z7B-7-34-1