7-48
MAINTENANCE
Replace Air Breather Element
--- every 2000 hours
d
WARNING: Hydraulic oil becomes hot during
operation. Severe burns may result if skin comes in
contact with hot hydraulic oil. Wait for the oil to cool
before starting any maintenance work.
Replacement Procedures
1. Park the machine following the same procedures as
described on page 7-6 for preparation of inspection/
maintenance work.
2. Before replacing the filter element, be sure to relieve the
air pressure from the hydraulic oil tank by pressing air
bleed valve (1).
3. Remove cap (2) and remove nut (3) by rotating it
counterclockwise.
4. Rotate cover (4) counterclockwise and remove it.
Remove element (5).
5. Install new element (5). Tighten cover (4) clockwise.
After cover (4) comes in contact with the inside element,
tighten the cover 1/4 turn further.
6. Install and tighten nut (3). Install cap (2).
m
Nut (3) : 8~10 N·m (0.8~1.0 kgf·m, 6~7.4 lbf·ft)
7. Take care not to allow water or dust to enter the
clearance (air discharge port) between cover (4) and
body (6).
f
NOTE: Replace the element at the recommended regular
intervals to keep the hydraulic oil clean and to extend the
service life of the hydraulic equipment.
T4A breather valve
2
3
4
5
6
95Z7B-7-42-2
1
Summary of Contents for ZW 370-6
Page 4: ...MEMO ...
Page 10: ...CONTENTS MEMO ...
Page 12: ...2 MACHINE NUMBERS Aftertreatment Device SCR TYPE MFG NO DOC TYPE MFG NO 95Z7B SCR4 95Z7B SCR4 ...
Page 53: ...SAFETY LABELS S 41 95Z7B S 40 ...
Page 148: ...1 84 OPERATOR S STATION MEMO ...
Page 218: ...OPERATOR S STATION 1 154 MEMO ...
Page 220: ...2 2 BREAK IN MEMO ...
Page 236: ...3 16 OPERATING THE ENGINE MEMO ...
Page 284: ...OPERATING THE MACHINE 5 28 MEMO ...
Page 426: ...MAINTENANCE 7 132 MEMO ...
Page 430: ...9 4 MAINTENANCE UNDER SPECIAL ENVIRONMENTAL CONDITIONS MEMO ...
Page 434: ...10 4 STORAGE MEMO ...
Page 440: ...11 6 TROUBLESHOOTING MEMO ...
Page 442: ...12 2 SPECIFICATIONS MEMO ...
Page 450: ...14 8 INDEX MEMO ...