K. Air Conditioner
Clean/Replace Air Conditioner Circulation/Fresh Air
Filters
Clean filters --- every 100 hours (or once a week
whichever come first)
Replace filter --- after cleaning filters 10 times (or
when the filters are severely clogged)
Clean Fresh Air Filter
1. Remove the filter:
The fresh air filter is installed behind cover (1) on the left
rear side of the cab exterior.
Open cover (1) with the starter key.
2. Loosen wing nuts (3) and remove plate (2).
3. Remove fresh air filter (4).
d
WARNING: When using compressed air pressure,
wear safety glasses or goggles.
IMPORTANT:
If compressed air delivery pressure is high, damage
to the filter fins may result.
Always use compressed air at the lower pressure
than 0.2 MPa (2 kgf/cm
2
, 30 PSI).
Keep the nozzle more than 500 mm (20 in) away
from the core surface.
4. Clean fresh filter (4) using compressed air.
2
4
3
92Z7-7-88
1
MNEC-07-043
Summary of Contents for ZW 370-6
Page 4: ...MEMO ...
Page 10: ...CONTENTS MEMO ...
Page 12: ...2 MACHINE NUMBERS Aftertreatment Device SCR TYPE MFG NO DOC TYPE MFG NO 95Z7B SCR4 95Z7B SCR4 ...
Page 53: ...SAFETY LABELS S 41 95Z7B S 40 ...
Page 148: ...1 84 OPERATOR S STATION MEMO ...
Page 218: ...OPERATOR S STATION 1 154 MEMO ...
Page 220: ...2 2 BREAK IN MEMO ...
Page 236: ...3 16 OPERATING THE ENGINE MEMO ...
Page 284: ...OPERATING THE MACHINE 5 28 MEMO ...
Page 426: ...MAINTENANCE 7 132 MEMO ...
Page 430: ...9 4 MAINTENANCE UNDER SPECIAL ENVIRONMENTAL CONDITIONS MEMO ...
Page 434: ...10 4 STORAGE MEMO ...
Page 440: ...11 6 TROUBLESHOOTING MEMO ...
Page 442: ...12 2 SPECIFICATIONS MEMO ...
Page 450: ...14 8 INDEX MEMO ...