MAINTENANCE
7-58
Refueling
1. Park the machine following the same procedures as
described on page 7-6 for preparation of inspection/
maintenance work.
IMPORTANT: The turbocharger may be damaged if the
engine is not properly shut down.
d
WARNING: Handle fuel carefully. Shut the engine
off before fueling. Do not smoke while you fill the
fuel tank or work on fuel system.
2. Check fuel gauge (1) on the monitor panel. Add fuel if
necessary.
IMPORTANT: Keep all dirt, dust, water and other
foreign materials out of the fuel system.
3. To avoid condensation, fill the tank at the end of each
day’s operation from filler port (2). Take care not to
spill fuel on the machine or ground.
Fuel tank capacity:
648 liters (171 gallons)
Drain Water and Sediment from Fuel Tank
--- every 1000 hours
Before starting to operate the machine, loosen drain
plug on the fuel tank bottom and drain water and/or
sediment from the fuel tank.
Tighten plug when no more water is draining, and only
fuel drainage is seen.
Drain plug (hex) width across flat: 24 mm (0.94 in), or
Hex socket width across flat: 12 mm (0.47 in)
1
2
1
115Z7-7-56-1
MNEC-01-002
115Z7B-7-56-2
Summary of Contents for ZW 550-6
Page 4: ......
Page 10: ...CONTENTS SPECIFICATIONS 12 1 Specifications 12 1 Intended Use 12 1 INDEX 14 1 ...
Page 12: ...MACHINE NUMBERS 2 Aftertreatment Device SCR TYPE MFG NO DOC TYPE MFG NO 95Z7B SCR4 95Z7B SCR4 ...
Page 54: ...SAFETY LABELS S 42 2 25 7 4 1 26 1 8 9 5 6 11 12 10 24 115Z7B S 42US ...
Page 148: ...OPERATOR S STATION 1 84 MEMO ...
Page 208: ...OPERATOR S STATION 1 144 MEMO ...
Page 210: ...BREAK IN 2 2 MEMO ...
Page 226: ...OPERATING THE ENGINE 3 16 MEMO ...
Page 274: ...OPERATING THE MACHINE 5 28 MEMO ...
Page 354: ...MAINTENANCE 7 70 MEMO ...
Page 418: ...9 4 MAINTENANCE UNDER SPECIAL ENVIRONMENTAL CONDITIONS MEMO ...
Page 422: ...10 4 STORAGE MEMO ...
Page 428: ...11 6 TROUBLESHOOTING MEMO ...
Page 430: ...SPECIFICATIONS 12 2 MEMO ...
Page 438: ...INDEX 14 8 ZW550 6 US MEMO ...