MAINTENANCE
7-66
95Z7-7-63-1
Clean Fuel Supply Pump Strainer
--- every 500 hours
IMPORTANT:
The supply pump strainer is assembled into the
joint bolt located at the inlet side of the supply
pump. This joint bolt is a component which
cannot be disassembled, so do not pull out the
strainer inside.
When cleaning the fuel strainer, do not
disassemble the strainer from the joint bolt (clean
it while being assembled).
1. Loosen joint bolt (1) and take out fuel strainer (2)
being assembled with joint bolt (1) from the fuel pipe
on the supply pump.
2. Clean the strainer in clean diesel fuel and blow off
dust with high-pressure air.
IMPORTANT: After cleaning the fuel strainer, bleed air
from the fuel supply system.
3. Reinstall strainer (2), tighten joint bolt (1) and closely
check the air-tightness of the strainer.
d
WARNING: After installing the strainer, wipe off
any spilled fuel.
4. Start the engine and run at low idle, and check for
fuel leaks.
Summary of Contents for ZW 550-6
Page 4: ......
Page 10: ...CONTENTS SPECIFICATIONS 12 1 Specifications 12 1 Intended Use 12 1 INDEX 14 1 ...
Page 12: ...MACHINE NUMBERS 2 Aftertreatment Device SCR TYPE MFG NO DOC TYPE MFG NO 95Z7B SCR4 95Z7B SCR4 ...
Page 54: ...SAFETY LABELS S 42 2 25 7 4 1 26 1 8 9 5 6 11 12 10 24 115Z7B S 42US ...
Page 148: ...OPERATOR S STATION 1 84 MEMO ...
Page 208: ...OPERATOR S STATION 1 144 MEMO ...
Page 210: ...BREAK IN 2 2 MEMO ...
Page 226: ...OPERATING THE ENGINE 3 16 MEMO ...
Page 274: ...OPERATING THE MACHINE 5 28 MEMO ...
Page 354: ...MAINTENANCE 7 70 MEMO ...
Page 418: ...9 4 MAINTENANCE UNDER SPECIAL ENVIRONMENTAL CONDITIONS MEMO ...
Page 422: ...10 4 STORAGE MEMO ...
Page 428: ...11 6 TROUBLESHOOTING MEMO ...
Page 430: ...SPECIFICATIONS 12 2 MEMO ...
Page 438: ...INDEX 14 8 ZW550 6 US MEMO ...