141
(3)
Homing
An operation to return the work to the base position (origin).
It is used for matching the position on the machine with the position on the software.
⚫
OLS (origin sensor) homing
The position in which OLS is turned ON
is the origin.
⚫
OLS+Z-phase homing
The Z-phase count position specified from
the position in which OLS is turned ON is
the origin.
⚫
ELS (end limit sensor) shared homing
The position in which the ELS position turns
ON and reversed from ON to OFF will be
the origin.
(4)
Timer operation (Dwell)
An operation which stops (does not move to the next operation) for the time set.
ON
OFF
OLS
Operation
ON
OFF
-ELS
Operation
ON
OFF
OLS
Z
Operation
Summary of Contents for motionCAT HCPCI-MNT720M