144
(3)
Machine interface
-
+
-ELS OLS DLS +ELS
(1)
Input
⚫
±ELS (Stroke End-Limit Sensor, Over Travel, OT)
Allocated at both ends of the direct movement axis.
The motion controller automatically stops the command pulse output when the ELS of the traveling
direction is detected.
When ELS is detected, the axis can move only in the opposite direction.
+/- polarity of the ELS must match the direction of the coordinates (traveling direction of the work).
⚫
OLS (Origin-Limit Sensor, origin sensor, near-origin sensor)
Used as the origin sensor of the sensor origin, or the deceleration sensor (near-origin sensor) during
Z-phase homing.
⚫
DLS (Deceleration-Limit Sensor, deceleration sensor)
Used as a deceleration sensor during a homing operation.
(4)
Interface for external machine synchronization
(1)
Output
⚫
CMP (Comparator output)
Compares the specified counter with the set comparator data to produce an external output
upon matching the comparator requirements.
(2)
Input
⚫
LATCH (Latch input)
Enables to latch the count value of the motion controller by latch input.
⚫
CLR (Clear input)
Enables to clear the count value of the motion controller by clear input.