22
Vcc
EMG
J1
24V
GND
SW12
1.8KΩ
1.8KΩ 680Ω
4.7KΩ
EMG
GND
GND
非常停止SW
(B接)
EMG
外部電源
(DC24V)
カット
MCAT520M側
(2)
Connection diagram of emergency stop input
To use the emergency stop function, cut the short pin labeled "EMG" on the circuit board.
As to 12V external power, turn ON the "SW12" switch on the circuit board.
Figure 2.1-7 Connection example of emergency stop input and internal circuit
(3)
J2, J3 Connectors for Motionnet communication (RJ45)
J2 (Line 1): Motionnet communication line 1
J3 (Line 2): Motionnet communication line 2
Pin
Function
1
Resistance to frame ground
2
Resistance to frame ground
3
S+
4
Reserved
5
Reserved
6
S-
7
Resistance to frame ground
8
Resistance to frame ground
Table 2.1-3 RJ45 (J2, J3) connector signals
2.1.6 Emergency Stop Input Detection
When an emergency stop is input, all connected motion modules are reset, and a cyclic communication error
occurs on the master board. After detecting cyclic communication error, check the status of the emergency
stop input of the option port.
* Note 1: Switch OFF (communication cable disconnection detection enabled) each communication
board’s communication settings switch 2 (DBG).
* Note 2: It is recommended that the type of emergency stop input should be one in which the ON-status
can be maintained until safety is confirmed.
Figure 2.1-8 Communication settings switch
F12
B
AC
D
E
6 5 7 8
9 034
F12
B
A
C
D
E
6 5 7 8
9 034
Communication settings switch
OFF ON
SPD0
SPD1
Debug
Term
N
O
DBG
Emergency stop SW
(NC)
External power
(DC 24V)
MCAT520M side
Cut
Summary of Contents for motionCAT HCPCI-MNT720M
Page 3: ......
Page 12: ...1 Warnings and Precautions...
Page 20: ...9 1 motionCAT Installation...
Page 109: ...98 4 Installation Guide...
Page 118: ...107 5 Device Driver Installation...
Page 122: ...111 6 Trial Operation...
Page 145: ...134 7 Accessories...
Page 147: ...136 8 Glossary...
Page 161: ...150 9 Connections to Drivers Supplied by Manufacturers...