69
(2)
P24-IN Module's DC 24V receiving terminal
●
C24V (or 12V) power supply to the receiving terminal.
●
Match the connection polarity to the one indicated on the plug (24/G).
●
Recommended wire material: AWG20 - 18 (0.5 to 0.9mm
2
stranded wire)
●
For fixing cables: Crimp tool YC-630 (JST)
Figure 3.6-3 Receiving terminal wiring
3.6.5 Connector Terminal Electrical Requirements
The following table shows the electrical requirements of connector signals described in the table above.
DIO 16/16 connector
IN/
OUT
Contents
Total of all EXTPOW
terminals
O
Allowable current: 1.6A or less
Per input
I
Consumption current: 8mA/point or less
Per signal output
O
Allowable current: 80mA/point or less
(However, total of 8 points must be 500mA or less.)
Table 3.6-4 Connector terminal electrical requirements
Housing: VHR-2N
Contact: BVH-41T-P1.1
Board-side post: B2PS-VH
A. Post
B. Housing (Fixed to the contact)
Summary of Contents for motionCAT HCPCI-MNT720M