103
Power receiving
terminal on the
module
4.2 Connections between Components and Power Supply System Wiring
4.2.1 Power Supply System Wiring for Slaves
(1)
Single piece of slave
A slave is equipped with +24V power receiving terminals on the communication board and each of the
modules.
⚫
Connect the power receiving terminals to the +24V power supply.
⚫
Match the connection polarity to the one indicated on the plug (24/G).
⚫
Recommended wire material: AWG20 - 18 (0.5 to 0.99mm
2
stranded wire)
⚫
For fixing cables: Crimp tool YC-630 (JST)
Figure 4.2-1 Power receiving terminals (Example of HMG 1-axis motion slave, HMG-P1)
(2)
Power supply system wiring for modules
Figure 4.2-2 One power supply for a slave
F
12
B
A CD
E
6 5
7
8
9
0
34
F
12
B
A CD
E
6 5
7
8
9
0
34
+
-
+24V
power
supply
Housing: VHR-2N
Contact: BVH-41T-P1.1
Board-side post: B2PS-VH
Power receiving
terminal on the
communication
board
A. Post
B. Housing (Fixed to the contact)