Assembly and Commissioning Instructions Servo amplifier D1-N
15.10.2015
11 / 183
2
Safety
DANGER!
This chapter serves to ensure the safety of everyone working in the vicinity of
the D1-N servo drive amplifier and who fits, installs, connects, operates,
maintains or disassembles it. Non-compliance with the following information
results in dangerous working conditions.
2.1
Intended use
The servo drive amplifiers of the D1-N range are suitable for operating brushless
synchronous servo motors, torque and linear motors in force and/or torque control
and speed and/or position control.
Please note that the rated voltage of the motors must be greater than or at least
the same as the intermediate circuit voltage supplied by the drive amplifier.
All drive amplifiers may only be used for the stated intended purpose.
The drive amplifiers are fitted as components in electrical equipment or machines
and may only be started up as integrated system components.
The machine manufacturer is obligated to produce a risk assessment for the ma-
chine. This is used as the basis for determining appropriate measures to prevent
injury and damage to property resulting from unforeseeable movements.
The drive amplifiers of the D1-N series can be connected directly to single-phase
or three-phase, earthed industrial networks (110- 230 V). They must not be operat-
ed in non-earthed networks or networks with unsymmetrical earthing with a volt-
age of more than 230V.
If the drive amplifiers are used in residential or commercial areas and small
plants, the user must take additional EMC filter measures.
The drive amplifiers may only be operated in a closed switch cabinet under the
permissible ambient conditions. For details, see Table 3.3 Technical specification
on page 20.
Only use copper cables for wiring in the switch cabinet.
The drive amplifiers of the D1-N series must not be used in unprotected outdoor
areas or areas at risk of explosion.
The D1-N servo drive amplifier can only be declared to be conforming if operated
with the accessories supplied and the other HIWIN components required (motor,
cables).