EHC-NERIS_ENG-Rev.0-23-09-2021
8
/
19
ELECTRIC SUPPLY CONNECTION
This appliance is equipped with a supply cable
H05V2V2-F 2x1.0mm²
that
should be connected to a fused spur in accordance with BS7671.
Requirements for Electrical Installations, Section 701.
It is recommended that the cable ends are crimped before connecting the
heater to the spur. This is to prevent any lose strands of flex being present
within the connection.
This appliance does not require earthing connection as it is double insulated.
Contact a fully qualified electrician for assistance.
TECHNICAL CHARACTERISTICS
Type
NERIS 500
NERIS 750
Rated Voltage
230 V~
230 V~
Rated
Frequency
50 Hz
50 Hz
Rated Power
Input
500 W
750 W
Electrical
Protection
Class
II
II
IP Protection
Deg.
IP24
IP24
Dimensions
(LxHxD) (mm)
505x780x100 505x1140x100
Weight (kg)
3,8
5,1
HOW TO PLACE TOWELS
Hang the towels on the heater horizontally across the rail from back to front.
It is recommended to use the upper horizontal tube of each tube set.
Do Not Cover completely as this will cause the rail to overheat!