background image

HJM_PECS_ENG_Rev.0_02-10-2019 

 Made in Spain  

14

/

24

 

 

POWER  LEVEL  INDICATOR

:  This  appears  on  the  left-hand  side  of  the  screen  and  it 

depends  on  the  programmed  temperature  level.  The  higher  the  programmed 
temperature  is,  the  greater  the  number  of  bars  shown  on  the  icon.  This  is 
instantaneous consumption visualization as, the higher the programmed temperature 
is, the higher the energy consumption is. 

 
 

 B

LOCK FUNCTION

: It is possible to block the radiator to prevent children from using it 

improperly or, for example, in a public space. 

In order to block/unblock the buttons, press the “Mode” 

 button and keep in pressed 

down for 3 seconds, until the icon appears (blocked) or disappears (unblocked). 

 
 

 

CONSUMPTION  METER  FUNCTION: 

This  function  allows  us  to  read  the  radiator’s 

consumption expressed in kWh. In order to do so, the power of the emitter must be 
previously adjusted, following these steps:

 

1.

 

Unplug the device from the electricity supply. 

2.

 

Simultaneously press buttons 

 and

.  

3.

 

Without  releasing  the  buttons,  plug  the  device  into  the  electricity  supply  for  at 
least 5 seconds until you can see the power adjustment function, as shown in this 
image:

 

 

4.

 

Use the 

 and 

 buttons to select your radiator’s power in Watts. 

5.

 

Confirm the selection with the 

button. 

This  operation  only  needs  to  be  done  the  first  time  and  then  it  will  stay  saved;  it  is  not 

necessary to repeat it every time you wish to consult consumption. 

Now you can read the consumption for various periods of time in the following way:

 

1.

 

Turn the radiator to off/stand-by mode. 

Summary of Contents for PECS

Page 1: ...HJM_PECS_ENG_Rev 0_02 10 2019 Made in Spain 1 24 ORIGINAL OPERATING INSTRUCTIONS Read carefully and retain for future reference Generic Top Electronics ...

Page 2: ...onfigured Comfort value Anti Frost Mode The thermostat keeps the room temperature above 7 C Holiday Mode The radiator enters the Anti frost mode for the period of time established by the user Timer Mode The thermostat operates as per a daily weekly programme defined by the user Turbo boost Mode The thermostat continuously feeds the resistance during the period that is adjustable by the user the ma...

Page 3: ...ture shows that the window has been closed Adaptive temperature control ASC This function anticipates radiator s operating start time regarding the programmed value only for Timer mode Safety for children This function reduces the radiator s surface temperature Power level indicator Instantaneous consumption visualisation Blocked Function to prevent accidental or improper use Consumption meter Thi...

Page 4: ...tton to turn the radiator on or to set the off stand by mode If the off stand by mode is activated the corresponding icon will appear on the screen and there will be two 0 5 second bleeps and the time will be shown When the device is turned on there will be a one second bleep and the icon will disappear ...

Page 5: ... desired temperature using the and buttons The minimum value that can be programmed is equal to the value of the temperature programmed in economy mode plus 0 5 C The maximum value is 32 C ECONOMY Mode Selecting this mode the radiator maintains the room temperature at the one selected for it In order to activate it follow these steps 1 Press the Mode button several times until the icon appears on ...

Page 6: ... and buttons it is possible to select the holiday period duration from 12 hours to 40 days with an increase of one hour 12 to 24 and with an increase of one day from 24 hours TIMER MODE In this mode the room temperature is maintained at the COMFORT or ECONOMY temperature depending on the programmes established for the different time intervals during the day P1 P2 or P3 In order to activate it foll...

Page 7: ...ion from 5 to 120 minutes When this function is activated the radiator operates at its maximum power ensuring that the room temperature does not exceed 32 C When the programmed time indicated by the countdown on the screen finishes the radiator returns to the previously established mode ECONOMY MODE 17 C Activating this mode the radiator operates at a pre established unchangeable temperature of 17...

Page 8: ... symbol disappears In order to activate this function please look at section 4 PROGRAMMING CHILD PROTECTION When this function is activated the temperature on the front part of the radiator is lowered so that it is safe when children are present Moreover this function means that the same radiator can be used in rooms smaller than the one it is installed in without significant changes in room tempe...

Page 9: ...r disappears unblocked CONSUMPTION METER FUNCTION This function allows us to read the radiator s consumption expressed in kWh In order to do so the power of the emitter must be previously adjusted following these steps 1 Unplug the device from the electricity supply 2 Simultaneously press buttons and 3 Without releasing the buttons plug the device into the electricity supply for at least 5 seconds...

Page 10: ...ious month current year previous year total radiator power indicator CONSUMPTION INDICATOR When the room temperature falls below the configured temperature the radiator s thermostat feeds the resistance and the symbol lights upon the screen with which it is consuming energy As soon as the room temperature reaches the selected temperature the thermostat stops feeding the resistance and the icon dis...

Page 11: ...day 6 Saturday 7 Sunday using the and buttons Press the button to confirm the selection 8 The current hour should then appear on the screen with the digits intermittently lighting up The hour can be modified using the and buttons Press the button to confirm the selection 9 The digits indicating the minutes light up intermittently on the screen The minutes can be set using the and buttons Press the...

Page 12: ...buttons to programme as you wish 7 Follow the same steps for each day of the week until reaching day 7 Sunday CALIBRATION OF THE TEMPERATURE SENSOR If the radiator is not installed in the optimum location to suitably detect the room temperature for example it is installed on a cold wall or there are draughts the measured room temperature may be different from the real temperature In order to achie...

Page 13: ...lection and go to the next function ASC ADAPTIVE TEMPERATURE CONTROL 1 Press the button to activate or deactivate the ASC function ON activate OFF deactivate 2 Press the button to confirm and go to the next function CHILD PROTECTION 1 Press the button to activate or deactivate the child protection function ON activate OFF deactivate 2 Press the button to confirm the selection If you have selected ...

Page 14: ...cleaning or maintenance operation Let it cool down before cleaning To avoid any risk of electrical shock clean the unit with a soft damp cloth to wipe the outside of the radiator and remove dust and dirt cloth Do not use detergent solvent abrasive products or any other chemical product to clean the radiator NEVER immerse the device in water or any other liquids You can use a vacuum or flexible bru...

Page 15: ...rhjm es Hereby declare that the following equipment complies with all the essential requirements for health and safety of European Directives 2014 30 UE EMC DIRECTIVE 2014 35 UE LV DIRECTIVE 2011 65 UE RoHS DIRECTIVE 2009 125 EC ErP Directive With reference to the application of the followinf standards 2014 30 UE EMC DIRECTIVE EN 55014 1 2006 A1 2009 A2 2011 EN 61000 3 2 2014 EN 61000 3 3 2013 EN ...

Page 16: ...eat output elmax 2 kW with electronic room temperature control NO In standby mode elSB 0 0005 kW electronic room temperature control plus day timer NO electronic room temperature control plus week timer YES Heat output 1500 Other control options multiple selections possible Nominal heat output Pnom 1 5 kW room temperature control with presence detection NO Maximum continuous heat output Pmax c 1 5...

Page 17: ... nominal heat output elmax 1 kW In standby mode elSB 0 0005 kW Contact details HERMANOS JULIÁN M S L Head Office Esposos Curie 44 Factory Gutenberg 91 93 Polígono Industrial Los Villares 37184 Villares de la Reina Salamanca España Tf 34 923 222 277 34 923 222 282 Fax 34 923 223 397 http www calorhjm es Requirements regarding ecodesign for local heating S S on 10 F 1 F 2 F 3 F 4 F 5 40 10 0 7 2 0 0...

Page 18: ...o optimise the recycling of the components and materials that comprise it and reduce the impact on human health and the environment The crossed out wheeled bin is marked on all Electrical and Electronic products to remind the consumer of their obligation dispose of them separately The consumer must contact the local authority or the vendor to learn about the correct disposal of his her old electri...

Page 19: ...ade in Spain 24 24 Made by HERMANOS JULIAN M S L Factory Gutenberg 91 93 Polígono Industrial Los Villares ES 37184 Villares de la Reina Salamanca Spain 34 923 222 277 34 923 222 282 Fax 34 923 223 397 Web www calorhjm es ESB 37295664 ...

Reviews: