Instruction Manual for QuickSet 

 
The  QuickSet  is  a  peripheral  device  for  connecting  to  the  Time  Code  Generators  ZZG5  and  ZZG6  of  HKW-
Elektronik GmbH. Its purpose is to store complex settings of the generator and to recall these settings simply on a 
single  key  press.  Because  of  the  simply  handling  the  QuickSet  is  especially  applicable  for  using  in  manufactoring 
environments for testing of units under test with different signal parameters. 
 

1.  Layout and Connection of the QuickSet 

 
The QuickSet must be connected to the RJ45-GPS-connector of the time code generator ZZG5/ZZG6 using a normal 
straight  through  (uncrossed)  network  cable.  On  the  topside  of  the  QuickSet  four  buttons  and  four  light-emitting 
diodes  (LED)  are  mounted.  Four  additional  buttons  and  four  additional  LEDs  can  be  connected  to  the  D-Sub-
Connector mounted at the side of the QuickSet. Each button recalls a determined complex setting of the time code 
generator out of the internal QuickSet Memory and transmits this setting to the generator. The corresponding LED 
identifies  the  latest  performed  setting.  So,  using  8  buttons  and  8  LEDs,  8  different  settings  of  the  generator  are 
storable  and  recallable.  Powering  of  the  QuickSet  with  12  V  dc  is  performed  via  the  network  cable  out  of  the 
generator ZZG5/ZZG6. 
 

2.  Preparing the ZZG5/ZZG6 

 
- firmware necessary for the ZZG5/ZZG6: 1.26 R 
If a firmware other than 1.26R (for example 1.26 without "R", or a lower version) is contained, a software update is 
necessary.  For  the  ZZG5  only  the  manufacturer  of  the  ZZG5  can  update  the  software  due  to  the  lack  of  the  USB 
interface. Updating the firmware of the ZZG6 is very simple, using the USB interface. 
 
For connecting the QuickSet to the time code generator, some special settings are required for the correct function of 
the Quickset: 
- Menu GPS: Sync msec must be "Off" 
- Menu Antenna Factor: must be "Off" 
- Output voltage level display must not be in dB-units but in absolute voltage units 
- The test signal menu of the ZZG5/ZZG6 must not be chosen. 
 
The last condition is automatically given after turning on the generator. The other settings are to be executed only 
once because the ZZG5/ZZG6 storage of settings is nonvolatile. 
 
The Quickset is to be connected to the generator using a network cable. 
 

3.  Operation of the Quickset 

For  protection  against  accidental  overwriting  of  the  memory  contents  there  are  several  operating  modes 
implemented, which are determined after turning on the generator or after connecting the QuickSet to the generator. 
By  simply  turning  on  the  generator  or  connecting  the  QuickSet  to  the  generator  the  QuickSet  always  operates  in 
normal mode. In normal mode changing of the memory contents is not possible. For changing the memory contents 
another  operating  mode  must  be  chosen  by  pressing  a  determined  button  while  turning  on  the  generator  or 
connecting the Quickset. The other operatimg modes are the so-called storage modes. There are two storage modes, 
one  including  setting  of  time,  and  the  other  without  storing  the  time.  Sometimes  it  is  necessary  to  change  signal 
parameters only, but the time of the generator must be kept. In other cases it is necessary to start the generator always 
with  the same well defined time. For this reason there exist two storage modes, which include or exclude the time 
setting. 
 
 