3-Way  24 Hour Timer–Damper Control

  

                  Easy to Follow Installation Instructions for the 

           

       HMI

 HOYME 

Adaptor TMADP-0240-3WS  

 

 
A Forced Air Heating System having a Fresh Air Intake Duct leading into the return plenum 
is often equipped with a 

P

ower 

O

pen Damper.  Usually the thermostat causes the damper 

to open for fresh air during furnace firing and allows the Damper to close when the fire 
stops. To open the Fresh Air Damper at times when the furnace is not firing requires the 
use of a 3-way switch (SPDT). 

This Timer/Adaptor, however, has been designed to 

override the normal operation of a fresh air damper to remain closed at certain 
intervals of the day due to the reoccurrence of foul outside air. 

 

 
 Purchasing a 3-way switch and the necessary extras can be time consuming. By 
purchasing this Ready Mounted 3-way switch with an interval timer, 

TMADP-0240-3WS,

 

you have eliminated the trouble of buying a 3-way switch, an interval timer, an 
electrical enclosure, all separately plus making the necessary connections and the 
problems of assembly.

 This adaptor comes completely assembled with simple, easy-to-

follow installation instructions which follow:  

            

1.  Mount the Adaptor 

TMADP-0240-3WS

 in a convenient place to 

operate the timer on or around the furnace area with two screws 
supplied.  

2.  Inside the adaptor are terminals 

“W”, “C”

 and 

“R”

 which are to 

be connected to corresponding terminals inside your furnace. Use 
3-C 18Ga. thermostat wire. 

3.  Connect adaptor terminals “

#2

” and 

#4

 to the two wires on the 

motor of the Hoyme 

Damper (Power Open Only).

                                                          

           

*Automatic Setting:

 When the 

Adaptor

 switch is in the 

“Automatic” 

position, the thermostat will operate normally which will cause the 
damper to 

open 

during the heating cycle and will allow the damper to 

close

 when the fire stops.  

                             *Manual Setting:

 In the 

“Manual”

 position, the switch will override the              

                              thermostat and will power the damper to remain in the

 open 

position.  

 
        *NOTE: Engaging the Timer by positioning the white pins outward overrides both the        
        “Automatic/Manual” settings of the 3-way switch and the thermostat to 

keep the fresh air

    

         

damper closed during times of foul outside air.

 See

 “Interval Timer”

 page 2.

 

      

 

This Schematic Wiring Diagram in also on the Inside Cover of the Adaptor 

1015-ld                                                                                                            Printed in Canada

 