background image

Installation

7 (10)

3.2

LED Indicators

Fig. 3

LED indicators

LED Indication

Meaning

GW Status

Green

Communication running

Red

Communication error

Red, flashing

Network interface error

LINK/ACT

Off

No link

Green

Link, no traffic

Green, flashing

Link and traffic

STS

Off

Not active or initializing

Green, fast flashing

No POWERLINK traffic

Green, single flash

Only asynchronous data.

Green, double flash

Asynchronous and synchronous data
No PDO data

Green, triple flash

Ready to operate
Asynchronous and synchronous data
No PDO data

Green

Operating
Asynchronous and synchronous data
PDO data is sent and received

Green, slow flashing

Stopped
Asynchronous and synchronous data
No PDO data

Red

Error (see ERR LED below)

ERR

Off

No error

Red

STS LED also red = fatal error
STS LED not red = non-fatal error

POWERLINK Slave Anybus

®

X-gateway

Network Interface User Manual

SCM-1202-091 1.1 en-US

Summary of Contents for Anybus X-gateway

Page 1: ...POWERLINK Slave Anybus X gateway Network Interface USER MANUAL SCM 1202 091 1 1 en US ENGLISH...

Page 2: ...ents associated with any particular implementation HMS Industrial Networks cannot assume responsibility or liability for actual use based on the data examples or illustrations included in this documen...

Page 3: ...Table of Contents Page 1 Preface 3 1 1 About This Document 3 1 2 Document history 3 1 3 Document Conventions 3 2 Description 4 2 1 Overview 4 2 2 Data Flow 4 3 Installation 5 3 1 Connectors 6 3 2 LED...

Page 4: ...This page intentionally left blank...

Page 5: ...ction leads to this result Bold typeface indicates interactive parts such as connectors and switches on the hardware or menus and buttons in a graphical user interface Monospaced text is used to indic...

Page 6: ...ission of data will never interfere and precise communication timing is guaranteed This mechanism is called Slot Communication Network Management SCNM SCNM is managed by one particular networked devic...

Page 7: ...tion tool for POWERLINK optional not included XDD file for POWERLINK download from www anybus com support Anybus Configuration Manager download from www anybus com support Basic Installation Steps 1 C...

Page 8: ...rnet connectors that are labeled X1 1 X1 2 when top mounted and X2 1 X2 2 when bottom mounted Fig 2 Network interface RJ45 pin layout Pin Function 1 TD 2 TD 3 RD 6 RD 4 5 7 8 reserved POWERLINK Slave...

Page 9: ...n single flash Only asynchronous data Green double flash Asynchronous and synchronous data No PDO data Green triple flash Ready to operate Asynchronous and synchronous data No PDO data Green Operating...

Page 10: ...NK Output PDO Size bytes Input SDO Size bytes Amount of acyclical I O data to exchange on POWERLINK Output SDO Size bytes Offline option Action if the POWERLINK network goes offline Clear reset the da...

Page 11: ...d dynamic mapping Ring redundancy Process Data Objects PDO for I O exchange Service Data Object SDO for explicit messaging 1 TPDO and 1 RPDO are supported Segmented SDO transfer Poll Reponse chaining...

Page 12: ...last page 2019 HMS Industrial Networks Box 4126 300 04 Halmstad Sweden info hms se SCM 1202 091 1 1 en US 2019 04 11 12834...

Reviews: