5.7. Configuration with Easy Config
5.7.1. Available Easy Config Modes
Bolt Serial may be configured using one of the pre-configured Easy Config modes.
NOTE
By default, the unit starts in Easy Config Mode 4. The unit awaits automatic configuration during 120
seconds or until receiving a configuration.
NOTE
To cancel Easy Config mode 11, the unit must be reset to factory default settings. See
Table 1. Easy Config modes
EC
Role
Description
1
Bluetooth PANU
Used for setting up point-to-point communication.
The unit scans for another unit in Config Mode 4. The unit listens for 40 seconds or until a configuration is established.
When a unit in mode 4 is detected: The scanning unit configures itself as a Bluetooth PANU Client, sends a connection
configuration to the detected unit, and restarts. The detected unit restarts and attempt to connect to the first unit as a
PANU Client.
2
N/A
Reset configuration to factory defaults.
3
N/A
Reset IP settings to factory defaults.
4
Client
Configure units in mode 4 as Clients.
Wait for automatic configuration. The unit listens for 120 seconds or until receiving a configuration.
When mode 4 is used with mode 1, 5 or 6, Serial Settings TCP Mode Client is activated automatically.
5
WLAN AP
The unit scans for other units in Config Mode 4 and configure them as Clients. Timeout occur after 120 seconds.
Restart as Access Point and connect Clients.
6
Bluetooth NAP
11
(any)
Enable PROFIsafe mode. The unit is locked in PROFIsafe mode.
No other configuration settings are changed.
The Easy Config modes are also described when selected in the built-in web interface. See
5.7.2. Easy Config Modes Time Considerations
Table 2. Easy Config modes time considerations
Mode
Timeout
1 and 9
The unit listens for 40 seconds or until a configuration is established.
4
The unit listens for 120 seconds or until receiving a configuration.
5, 6, 7 and 8
The unit scans for 120 seconds, then timeout occur.